EX500 Serial System

EX## - OME0008

3 -2. Gateway ( GW ) Unit

How to Order

E X 5 0 0 - G D N 1

Network communication

 

protocol

GW Unit compatible

 

DN

DeviceNet

 

Nil

DeviceNet

PR

PROFIBUS-DP

 

PROFIBUS-DP

 

 

AB

Remote I/O ( RIO )

 

-X1

Remote I/O ( RIO )

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

US

 

 

 

 

 

 

 

 

 

 

RUN

 

 

 

 

 

 

 

 

 

 

SOL

 

 

 

 

 

 

 

 

 

 

COM

 

 

 

 

 

 

 

 

 

 

ERR

 

EX5GATEWA

 

 

 

 

 

 

 

24VDC

 

 

 

 

 

 

 

 

 

 

00

Y

UNIT

 

 

 

 

 

 

 

 

SER

 

 

 

 

 

 

 

 

IES

 

 

 

 

 

 

S

 

 

 

 

 

 

 

 

 

 

MC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RISE

 

 

 

 

 

 

NI ED MA

 

N

LA C IP

 

 

 

 

 

 

O. E

DO PU IN

 

 

 

 

 

AN AP J

 

5 P6 ITU PT

UO

/GATTL VO

 

 

 

 

 

 

 

4 6

42

E

 

COM

 

 

 

 

 

64/20/C VD

05XE

D

 

 

 

 

A m0

-0

 

 

 

 

 

 

 

 

BAG

 

 

 

 

 

 

SU

C

1X-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PE

.

Gateway ( GW ) Unit

Gateway ( GW ) Unit specification

Item

Specification

Models

 

EX500 - GAB1 - X1

 

EX500 - GDN1

 

EX500 - GPR1

Rated voltage

 

 

 

 

 

24V DC

 

 

 

 

 

 

 

Input and control power supply : 24V DC ±10%

 

Power supply

 

 

 

Solenoid valve power supply : 24V DC +10% / -5%

 

 

 

( Warning of voltage drop given lower than approx. 20V )

 

voltage

 

 

 

 

 

Communication power

 

 

 

 

 

 

-

 

 

supply for DeviceNet :

 

 

-

 

 

 

 

 

 

11V DC to 25V DC

 

 

 

Current

 

 

 

 

 

200mA or less ( only GW Unit )

 

 

 

 

 

 

 

 

Communication power

 

 

 

consumption

 

 

-

 

 

supply for DeviceNet :

 

 

-

 

 

 

 

 

 

50mA or less

 

 

 

Input / Output

 

 

 

Maximum 64 inputs / Maximum 64 outputs

 

 

points

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input / Output

 

 

 

4 branches ( one branch 16 inputs / 16 outputs )

 

branches

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M12 connector ( 8 pin, socket )

 

 

 

Pin NO.

 

 

 

 

 

 

 

 

1.

RD +

2.

RD -

 

 

 

1

2

Branch

3.

TD +

4.

TD -

7

8

3

 

 

 

 

 

 

connector

5. 24V DC ( for solenoid valve)

 

 

6.

0V DC ( for solenoid valve)

6

4

 

 

7. 24V DC ( for power source )

5

 

 

 

 

 

 

 

 

 

 

 

8.

0V DC ( for power source )

For GW Unit

 

 

 

 

Length of branch

Less than 5m ( Less than 10m Max. Length )

 

 

cable

 

 

 

 

 

 

 

 

 

Communication

Communication protocol : SMC original protocol

 

 

Communication speed

: 750 k bit / sec. ( DeviceNet, PROFIBUS-DP )

 

form

 

 

 

 

 

: 500 k bit / sec. ( Remote I/O (RIO))

 

 

 

 

 

 

 

 

 

 

M12 connector ( 5 pin, plug )

 

 

 

Pin NO.

 

 

 

 

 

 

 

 

1. 0V ( for solenoid valve)

2

 

Power

2.

24V DC + 10% / - 5% 3A Max.

1

 

 

 

 

 

 

 

 

 

( for solenoid valve)

5

 

Supply

 

 

 

3. 0V ( for power source ( input and control ) )

 

 

connector

 

 

4. 24V DC±10% 3A Max.

3

4

 

 

 

 

 

( for power source ( input and control ) )

For GW Unit

 

5. PE ( Protective earth )

 

 

 

 

 

 

 

 

 

 

 

Weight

 

 

 

 

 

470g

 

 

- 8 -

Page 9
Image 9
SMC Networks EX500 manual Gateway GW Unit specification, How to Order 5 0 0 G D N