3. Specification and Product numbers

3 -1. General specification of EX500 series

Item

Specification

 

 

Enclosure

IP65

Standard

UL,CSA,CE

Withstand voltage

1500V AC 1min. ( between PE - external terminal package )

Insulation resistance

2MΩor more

( 500VDC meg. between PE - external terminal package )

 

Momentary power failure

1m sec. or less

Ambient temperature

+5to +45

Ambient humidity

35% to 85%RH ( without condensation )

Preservation temperature

- 25to 70

 

10Hz to 57Hz 0.35mm ( constant amplitude )

Vibration proof

57Hz to 150Hz 5G ( constant speed )

 

2 hours per each direction of ±X,Y and Z

Shock resistance

Peak value : 15G

3 times per each direction of ±X,Y and Z

 

Applicable altitude

Less than 1000m above sea

EMC Directive ( 89 / 336 / EEC )

EN50081-2 / 1993, EN55011 / 1998 +A1 : 1999, EN50082-2 / 1995, EN61000-6-2 / 1999

Electromagnetic Emission

Item

Test Procedure

 

Specification

Criterion

Radiated Electric Field

EN55011 : 1998 +A1

 

30MHz to 230MHz, 230MHz to 1GHz

Group 1

Strength

: 1999

 

( Distance : 10m )

Class A

Electromagnetic Susceptibility ( Immunity )

 

 

Item

Test Procedure

 

Specification

Criterion

ESD

EN61000-4-2 : 1995 /

 

±4kV contact

B

A1 : 1998

 

±8kV air discharge

 

 

 

RS :

EN61000-4-3 : 1996 /

 

80MHz to 1000MHz

 

Radiated Susceptibility

 

A

A1 : 1998

 

10V / m ( 1kHz AM 80% )

( amplitude modulated)

 

 

 

 

 

 

RS :

 

 

900±5MHz

 

Radiated Susceptibility

ENV50204 : 1995

 

10V / m

A

( pulse modulated )

 

 

( 200Hz Pulse Mod. Duty 50% )

 

CS :

 

 

 

 

Conductive

EN61000-4-6 : 1996

 

0.15MHz to 80 MHz

A

Susceptibility

 

10V ( 1kHz AM 80% )

 

 

 

( amplitude modulated)

 

 

 

 

EFT / Burst,

EN61000-4-4 : 1995

 

±2kV

B

DC power lines

 

( 5 / 50ns, 5kHz )

 

 

 

EFT / Burst,

EN61000-4-4 : 1995

 

±2kV

B

control lines

 

( 5 / 50ns, 5kHz )

 

 

 

Surge,

EN61000-4-5 : 1995

 

±1kV ( Common )

B

interface lines

 

 

 

 

 

- 7 -