5.1 Specifications

FOR HVAC INSTALLER ONLY

5.DEH 3000 Digital Control Installation Instructions

Control Part No. 4026570

5.1 Specifications

 

Part # (P/N)

4026570

Model:

DEH 3000 Digital Control

Electrical:

24 VAC

Humidity Range:

10 – 95% RH

Humidity Accuracy:

+/- 5%

Output:

3 Amps 24 VAC

Relay Capacity

5 Amps

Temp Range/Accuracy

2%

Size

4.95" wide x 4.19" high

FOR HVAC INSTALLER ONLY:

5.2 Installation

This control panel must be installed in the conditioned space and in accordance with all applicable codes and standards. Follow the instructions below when installing and setting this control.

5.2A Install Instructions

1.Separate the front panel from the back panel by depressing the middle sections of the top and bottom of the front panel.

2.Line the back panel up against the wall or flat surface onto which it is to be mounted and drill in the appropriate mounting holes.

3.Insert the screws and tighten down so they extend approximately 1/8” from the back plate.

4.Align the back panel so that the control is level.

5.Tighten the screws to lock into position.

6.Make the electrical connections to the terminals on the back panel as shown in the wiring diagram.

7.Reassemble the front to the back panel. Connect at the top first, then at the bottom.

8. Test connections (see Section 2.6)

5.2B Wiring

WARNING: DO NOT ALLOW THE YELLOW LEAD FROM THE ULTRA-AIRE TO CONTACT THE RED OR WHITE LEADS FROM THE ULTRA-AIRE OR DAMAGE TO THE TRANSFORMER WILL RESULT

WARNING: UNPLUG ULTRA-AIRE BASE UNIT BEFORE WIRING CONTROL.

The installer must supply the wiring between the Ultra-Aire and the control panel. Be sure to safely route the control wires to prevent damage during installation. Be careful not to cross the wires when connecting the Ultra-Aire and the remote control panel or damage to the transformer may result.

The remote control of the Ultra-Aire is powered by a low voltage circuit (24 VAC) and must NEVER contact or be connected to a high voltage circuit. Some of the control wires leaving the Ultra-Aire may not be used with certain control panels and should be left safely disconnected with wire nuts taped onto the stripped ends. Be sure to consult the electrical schematic in this manual or on the front panel of the Ultra- Aire before making the control connections.