2.2 Transporting the Phoenix

2.Locate the two mounting holes for the handle assembly on the Mini-Guardian HEPA System cabinet. They are located in close proximity to the top of the cabinet near the corners. A lock nut should be visible through each of the mounting holes and is held in place by a retainer plate secured to the cabinet shell. Verify lock nut is visible in each mounting hole.

4.Tighten each of cap screws using the 8mm hex key until the handle assembly is secured against the cabinet surface and all space between parts is eliminated.

Figure 2: Mounting holes

3.Place a socket head cap screw (M10 x 35mm) into each of the holes in the handle end brackets. Position the handle assembly up against the Phoenix Mini-Guardian HEPA System cabinet so as to align the cap screws with the mounting holes in the cabinet.

It may be necessary to tilt the handle assembly up at a slight angle in order to align the screws with the lock nuts. Use the 8mm hex key to press the cap screws into the mounting holes and engage the threads of the lock nuts.

Figure 3: Handle tilting for assembly

Figure 4: Tightening screws

2.2 Transporting the Phoenix

The Phoenix Mini-Guardian HEPA System should be upright when transported by vehicle. It may be tipped on to its back for loading and moving by hand or for use on location.

2.3 Location

Note the following precautions when locating the Phoenix Mini-Guardian HEPA System:

·It is designed to be used INDOORS ONLY.

·If used in a wet area, plug it into a GROUND FAULT INTERRUPTER.

·DO NOT use the Phoenix Mini-Guardian HEPA System as a bench or table.

·The air inlet on top & the side outlets should be at least 1 foot from walls and other obstructions to airflow.

2.4 Electrical Requirements

The Phoenix Mini-Guardian HEPA System can be plugged into a grounded 15 Amp circuit. It draws about 2 Amps with clean filters and no ducting. The amp draw will decrease slightly with added ducting and as the filters load with particulate.

If an extension cord is required, it must have a minimum of 18 gauge conductors if 25 feet long or less and 16 gauge conductors if greater than 25 feet long.