Thermador C301, C271 Table Of Contents, Unpacking, Cabinet Preparation, Wall Mounted Units, Oven

Models: CM301 C272 S301 S272 S302 TRUE C301 CM302 CJ302 SC272 SCD272 C302 SC301 C271

1 8
Download 8 pages 3.83 Kb
Page 2
Image 2
TABLE OF CONTENTS

TABLE OF CONTENTS

 

STEP 1: UNPACKING

2

STEP 2: CABINET PREPARATION

2

STEP 3: ELECTRICAL INSTALLATION

6

STEP 4: INSTALLING THE OVEN

7

STEP 5: INSTALLING THE BOTTOM TRIM

8

STEP 1: UNPACKING

Cut the bands from the carton. Carefully remove the carton, fillers and all packing material. Included with your new Thermador oven are the following:

Number of Racks Per Oven Model

 

C272 /C302 /CM302

6

SCD272 /SCD302

6

SC272 /SC302

5

S272 /S302 /CJ302

4

SC301 /C271 /C301 /CM301/ SMW272/SM272 3

S301

2

One 2-Piece Broiler Pan

Care & Use Manual

Installation Instructions

Bottom Trim

Installation Screws (Packet)

Quick Guide

Cookbook (C, CJ and CM models only)

Fig. 1 Oven Base Attachment

 

Remove Screws -

Shipping base skid

4 places

The bottom trim is shipped, wrapped in waxed paper, on top of the unit and should not be unpacked until the final step when the oven has been placed in the cabinet. See Fig. 6.

STEP 2: CABINET PREPARATION

The cabinet cutout dimensions for wall mounted and under the counter installations are shown in Figs. 2 and 3, respectively.

It is good practice, when oven is installed at the end of a cabinet run, adjacent to a perpendicular wall or cabinet door, to allow at least 1/4" space between the side of the oven door and the wall/door.

Wall Mounted Units —

For oven support, install 2 x 4’s extending front to back flush with the bottom and the side of the opening.

The supporting base must be well secured to the floor/ cabinet and level with the floor line.

NOTE: The conduit box for double ovens (S272, SC272, SCD272, S302, SC302, SCD302, C272, C302, CM302, CJ302, SMW272 and SM272) should be located above the unit to facilitate connecting and servicing. For single ovens (S301, SC301, C271, C301 and CM301) the conduit box may be installed either above or below the unit. If the conduit box is installed below the unit, a 2" diameter hole or space is required between the back wall and the right rear of the 2 x 4 supports. See Fig. 2

When an oven is installed, the cabinet base must be capable of supporting the oven weight as listed below:

Oven

Pounds

Kilograms

S-series Single Oven

165

75

C-series Single Oven

210

95

CM Single Oven

240

109

S-series Double Oven

330

150

C-series Double Oven

355

161

CM/CJ Double Oven

370

168

Page 2

Page 2
Image 2