Thermador SC272 Electrical connection, Electrical Installation, Grounding, Thermador Cooktops

Models: CM301 C272 S301 S272 S302 TRUE C301 CM302 CJ302 SC272 SCD272 C302 SC301 C271

1 8
Download 8 pages 3.83 Kb
Page 6
Image 6
Under-The-Counter Installation with

 

 

Table 1

 

 

Under-The-Counter Installation with

 

 

Thermador Cooktops

 

Model
Type of Cooktop

 

 

Model

 

Type of Cooktop

Number

 

 

 

Number

 

 

 

 

 

 

 

 

 

CER30

 

 

 

CGX304

 

 

CE304

Glass Ceramic top - electric

 

 

CGX365

 

Glass Ceramic top - gas

CE365

 

 

 

CGX456

 

 

CE456

 

 

 

 

 

 

 

 

 

SGC304R

 

 

 

 

 

 

 

 

*TMH30

 

 

 

SGC365R

 

 

 

 

 

SGC456R

 

Steel top - gas

*TMH36G

Steel top - electric coil

 

 

 

 

 

SGCS304R

 

 

*TMH45P

 

 

 

 

 

 

 

 

SGCS365R

 

 

 

 

 

 

 

 

GGS30

Glass top - gas

 

 

SGCS456R

 

 

 

 

SGS36G

 

 

GGS365

 

 

 

 

 

 

 

 

CD365

 

Glass Ceramic top - gas and electric

 

 

 

 

 

 

 

 

 

CD456

 

 

 

 

 

 

 

 

 

* See Figure 4

 

 

 

 

 

 

 

 

 

 

 

 

 

STEP 3: ELECTRICAL INSTALLATION

All model ovens on the front cover are dual rated, designed to be connected to either 120/240V AC or 120/ 208V AC, 60 Hz, 4 wire, single-phase power supply.

The S301 and SC301 require a 20-amp circuit. The C271, C301, CM301 SMW272 and SM272 require a 30-amp circuit. The S272, SC272, SCD272, C272, S302, SC302, SCD302 and C302 require a 40-amp circuit. The CM302 and CJ302 require a 50-amp circuit.

The electrical supply should be a 4-wire single-phase AC. Install a suitable conduit box (not furnished) as shown in Figures 2 or 3.

Electrical connection:

1.Connect the red oven wire to the red electrical supply wire (hot wire).

2.Connect the black oven wire to the black electrical supply wire (hot wire).

3.Connect the white neutral oven wire to the white neutral (not bare ground) electrical supply wire.

4.Connect the bare ground oven wire to the bare ground electrical supply wire.

The conduit cable, where connected at the oven, swiv- els. Rotate conduit cable upward (or downward) and direct through hole prepared in cabinet to attach to J- Box.

To facilitate service, the flex conduit must not be shortened and should be routed to permit temporary removal of the oven.

Fig. 4- TMH Models Installation Minimum Wall Clearance

B

Combustible Wall

 

 

Countertop

 

Cutout

A

 

A

 

 

 

Cooktop

Minimum Distance to Combustible Wall

 

 

 

Model

A (cm)

B (cm)

TMH30

3" (7, 6 cm)

2" (5, 1 cm)

TMH36G

2-7/8" (7, 3 cm)

2-3/4" (7, 0 cm)

TMH45P

3-3/4" (9, 5 cm)

2" (5, 1 cm)

GROUNDING

IMPORTANT: Local Codes might vary, installation, electrical connections and grounding must comply with all applicable local codes.

1.If local codes permit grounding through the electrical supply neutral, connect both the white neutral wire to the bare ground wire from the oven to the white neutral electrical supply wire.

2.If local code requires a separate ground, connect the white oven neutral wire to the white neutral electrical supply wire and the bare ground oven wire to the bare ground electrical supply wire.