CONNECT GAS SUPPLY, Continued

For Massachusetts Installations:

1.Shut-off valve must be a “T” handle gas cock.

2.Flexible gas connector must not be longer than 36 inches.

3.Not approved for installation in a bedroom or a bathroom unless unit is direct vent.

ELECTRICAL CONNECTION / FINAL CHECK / BEFORE FIRST USE

4A. CONNECT ELECTRICAL SUPPLY – CGX MODELS

Before connecting the 5-foot supply cord to wall receptacle make certain that gas shut-off valve is in the “OFF” position.

! WARNING: Before turning on the power, be sure that all controls on the cooktop are turned "OFF"

4B. CONNECT ELECTRICAL SUPPLY – CD MODELS

1.Attach flexible conduit to the junction box.

2.Connect the cooktop lead wires to the junction box supply wires in proper phase: connect black (L1) to black, white (neutral) to white, red

(L2) to red and bare wire to ground.

NOTE: If the cooktop is installed and connected as specified above, it will be completely grounded in compliance with the National Electrical Code.

5.FINAL CHECK

After electrical connection is complete, place each burner cap in correct notched position and check operation of electric igniters. See Page 16. Check flame characteristics. Flame should be blue with no yellow tip.

6.BEFORE FIRST USE

Remove everything from the cooktop surface and apply Cooktop Cleaning Creme (packaged with cooktop), as directed in Care section of the manual, Page 8.

! CAUTION: Your cooktop surface needs to be cleaned daily. Refer to the Care and Use section before using it for the first time.

Page 24