Thermador CIT30 manual Power Supply

Models: CIT30

1 25
Download 25 pages 41.13 Kb
Page 5
Image 5
Power Supply

Cabinet requirements

The

distance from the top of the cooktop to the bottom

of cabinets above

 

A =

30" (762 mm) min. This distance can be reduced to A = 24" (610

 

 

bottom of the wood or metal cabinet

is protected by not

less than 1/4"

(6

 

flame

retardant millboard, covered by no. 28 MSG sheet steel, 0.015" (0.4

 

thick

stainless steel, 0.024" (0.6 mm)

aluminum or 0.020"

(0.5 mm) thick

co

 

Verify

that cabinets above the cooktop

are a maximum of

B=13" (330mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical requiements

You can

find

the identification plate with the electrical specifications on

the

 

underside of the appliance. See •Product Data Plate" under •Service" for da

 

location.

The

junction box must be located within 3 feet of the cooktop

co

 

It should

be

easily accessible for service purposes.

 

12" Approximate

•J" Box

(Conduit approx. 3 feet)

Power Supply

Models CIT302DS, CIT304DS, CIT304EM

40 Amp circuit breaker

240 Volt, 3 Wire, 60 Hz

208 Volt, 3 Wire, 60 Hz

All with 1m flexible conduit (included)

6

Page 5
Image 5
Thermador CIT30 manual Power Supply