Sun Microsystems X4200 M2 manual Environment Specifications, Power Source Requirements

Models: X4200 M2

1 48
Download 48 pages 15.89 Kb
Page 32
Image 32

 

supported languages

 

 

Networking Software

ONC™ , ONC+(TM), NFS(TM), WebNFS(TM), TCP/IP, SunLink™, OSI,

 

MHS, IPX™ /SPX, SMB technologies, and XML

 

 

Management

CLI (in-band and out-of-band), IPMI 2.0 (in-band and out-of-band), SNMP

 

(out-of-band only)

 

 

Physical Specifications

Description

U.S.

International

Height

3.5 inches (2 RU)

89 mm

 

 

 

Width

17.4 inches including bezel

442 mm including bezel

 

16.7 inches no including bezel

424 mm not including bezel

 

 

 

Depth

20 inches max depth

508 mm max depth

 

19 inches to the connector plane

483mm to connector plane

 

 

 

Weight, approximate (without PCI cards or

35lbs (2 disk version)

16 kgs (2 disk version)

rack mounts)

37.2lbs (4 disk version)

17 kgs (4 disk version)

 

 

 

Environment Specifications

These are the environmental specifications for the NetraTM X4200 server.

Specification

Operating

Non-Operating

Temperature

5°C to 40°C, (41°F to 104°F)

-40°C to 70°C (-40°F to 158°F)

 

Short Term -5°C to 55°C (23°F to 131°F)

 

 

 

 

Relative Humidity

5% to 85% relative humidity, noncondensing

Up to 93% relative humidity

 

Short term: 5% to 90% relative humidity,

noncondensing, 38°C (100.4°F) max

 

noncondensing, but not to exceed 0.024 kg

wet bulb

 

water/kg dry air (0.053 lbs. water/2.205 lb. dry

 

 

air)

 

 

 

 

Altitude

Up to 3000 meters (9,850 feet) @40°C

Up to 12,000 meters (40,000 feet)

 

 

 

Power Source Requirements

The Netra X4200 M2 server has two autoranging AC or DC power supplies. To ensure redundant operation of the power supplies, the two power inputs should be connected to separate power sources.

These are the electrical limits and ranges for the Netra X4200 M2 server utilizing 550W power supplies.

Description

AC Specification

DC Specification

Operating input voltage range

100 to 240 VAC, 50 to 60 Hz

-48VDC or -60VDC (nominal)

 

 

-40VDC to -75VDC (range)

 

 

 

Maximum operating input current

6.5A at 100 to 120 VAC

12.7A at -48VDC

 

3.2 A at 200 to 240 VAC

10.2A at -60VDC

 

 

 

Maximum heat dissipation

2150 BTU/hr.

2085 BTU/hr.

 

 

 

Just the Facts, August 2007 Sun Confidential: Internal and Sun Channel Partners Use Only