Feature | Function | Benefit | |||
• | DDR2/667 memory with | • ECC helps to ensure data | • | Increases memory reliability, | |
| ECC |
| integrity with automatic error |
| helping to reduce the chances of |
|
|
| correction in case a single bit |
| system downtime caused by |
|
|
| is affected by such events as |
| memory failures |
|
|
| alpha particle hitting a |
|
|
|
|
| memory cell |
|
|
|
|
|
|
| |
• | Hardware RAID support | • | Supports either | • Provides data redundancy and | |
| provided by the onboard |
| RAID 1 (Integrated Mirror) |
| increased performance at no |
| disk controller |
| volumes, or |
| additional cost. |
|
|
|
|
| |
|
|
| Stripe) volumes |
|
|
|
|
|
|
|
|
• | NEBS | • | Enables continuous operation | • | Maximizes availability and |
| certification |
| in earthquake Zone 4 |
| decreases downtime due to |
|
|
| environments: complies with |
| environmental conditions |
|
|
| regulatory regulations for |
|
|
|
|
| deployment in central office |
|
|
|
|
| environments |
|
|
|
|
|
|
| |
• | Ruggedized enclosure | • Provides the highest levels of | • | Increases reliability and | |
|
|
| protection from temperature |
| availability. Minimizes downtime |
|
|
| fluctuations, humidity, |
| due to enviromental conditions |
|
|
| vibration, pollutants, or other |
|
|
|
|
| air contaminants such as dust; |
|
|
|
|
| resist/retard fire or other |
|
|
|
|
| electrical hazards |
|
|
|
|
|
|
| |
• | • | Provides ease of | • Reduces service time and gives | ||
| kit and flip down bezel |
| serviceability and ability to |
| customers the flexibility to rack |
| are standard with every |
| rack system in a variety of |
| mount the Netra X4200 in a variety |
| system. Other rackmount |
| industry racks |
| of different industry racks |
| kits available: |
|
|
|
|
| post, |
|
|
|
|
| 600mmx600mm, and 19- |
|
|
|
|
| inch 4 post slide rail. |
|
|
|
|
|
|
|
|
| |
• | Dry Contact Alarms | • | Four programmable alarms | • Enables Telco operators to use a | |
|
|
| are available in the Netra |
| relay to signal fault conditions to a |
|
|
| X4200 M2 server,these |
| rack or control room panel as well |
|
|
| include Critical, Major, |
| as an alarm monitoring system |
|
|
| Minor, and User. Critical, |
|
|
|
|
| Major, and Minor alarms are |
|
|
|
|
| to be used to denote |
|
|
|
|
| corresponding system states |
|
|
|
|
| while User alarm is user- |
|
|
|
|
| definable |
|
|
|
|
|
| ||
• | Redundant AC/DC power | • A fully configured system can | • Increase availability and helps | ||
| supplies with separate |
| run on one power supply; the |
| ensure uptime of critical |
| power cords |
| second power supply is for |
| applications. |
|
|
| redundancy and load sharing |
|
|
|
|
|
|
|
|
Just the Facts, August 2007 Sun Confidential: Internal and Sun Channel Partners Use Only | 8 |