30” Under-the-counter-Units
A single oven installed under the counter allows for the installation of most Thermador Gas or Electric non-Cook’n’Vent® Model Cook- tops. Downdraft units cannot be installed in this configuration; Thermador overhead ventilation is recommended.
Some TMH cooktops require addi- tional clearances to combustible walls.
A Thermador cooktop should be installed on the same center line as the under-the-counter single oven. Follow the installation in- structions provided with cooktop for installation of cooktops. 3 3/4” inches (95mm) minimum is re- quired from the top of the counter- top to the top of the cutout opening for under-counter installation with Thermador cooktops. If the type of cabinet or countertop thickness does not provide for this minimum space, the cabinet base may have to be lowered, into the toe space, to provide the necessary space above the oven. However, a 4” minimum distance between the floor and the oven bottom must re- main.