Electrical Installation
All model ovens on the front cover are dual rated, designed to be connected to ei- ther 208/240V AC, 60 Hz, 4 wire,
Model |
| Circuit Required | |
|
|
|
|
| 208V, 60 Hz |
| 240V, 60 Hz |
|
|
|
|
M271, M301 | 25 AMP |
| 30 AMP |
|
|
|
|
ME301, MEW301 | 30 AMP |
| 30 AMP |
ME271, PO301, |
|
|
|
POD301, DE301, |
|
|
|
DEC301 |
|
|
|
|
|
| |
ME302, MED302 | 40 or 50 Amp circuit. Refer to local electrical codes | ||
ME272, MED272, | for | ||
|
|
| |
PO302, POD302, |
|
|
|
PODC302, DE302, |
|
|
|
MEM271, MEM301, |
|
|
|
POM301, MEMC301, |
|
|
|
MEMCW301, |
|
|
|
MEMW271, MEMW301, |
|
|
|
POMW301 |
|
|
|
|
|
|
|
The electrical supply should be a
Important: Local Codes may vary, installation, electrical connections and ground- ing must comply with all applicable local codes.
If local codes permit grounding through the electrical supply neutral, connect both the white neutral wire and the bare ground wire from the oven to the white neutral electrical supply wire.
Electrical Connection
1.Connect the red oven wire to the red electrical supply wire (hot wire).
2.Connect the black oven wire to the black electrical supply wire (hot wire).
3.Connect the white neutral oven wire to the white neutral (not bare ground) electrical supply wire.
4.Connect the bare ground oven wire to the bare ground electrical supply wire.
The conduit cable, where connected at the oven, swivels. Rotate conduit cable up- ward (or downward) and direct through hole prepared in cabinet to attach to
To facilitate maintain serviceability, the flex conduit must not be shortened and should be routed to permit temporary removal of the oven.
13