STEP2: CABINETPREPARATION

1.The range is a free standing unit. If the unit is to be placed adjacent to cabinets, the clearances shown in Fig. 1 are required. The same clearances apply to island installations, except for the overhead cabi- nets, which must have a space wide enough to accept the flared island hood, as indicated in Fig. 1.

2.The PRDS48 Ranges must be placed with the oven door projecting out from the cabinet face. The cabinet face should line up with the oven front frame, which is the surface that the oven door closes against. (See Fig. 2b and 2c illustrating side views of 48" ranges.)

3.The gas and electrical supply should be within the zones shown in Fig. 3a, 3b and 3c.

4.The maximum depth of over head cabinets installed on either side of the hood is 13".

5.Any openings in the wall behind the range and in the floor under the range must be sealed.

6.When there is less than a 12"

horizontal clearance between combustible material ∆ and the back edge of the range above the cooking surface, a Thermador Low Back or High Shelf backguard must be installed. (See Fig. 2a). When

clearance to combustible material ∆ is over 12", a Thermador Island Trim may be used. (See Fig. 2b). Except in the case of 30" Ranges, backguards must be ordered separately. Figures 2a, 2b and 2c indicate the space

required for each type of backguard.

7.Always keep appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

8.Do not obstruct the flow of combustion and ventilation air to the unit.

CAUTION:

Do not install the Model PRDS48 ranges such that the oven door is flush with the cabinet face. A flush installa- tion could result in damage to the cabinets due to exposure to high heat.

As defined in the “National Fuel Gas Code” (ANSI Z223.1, Latest Edition).

FIG. 1 Cabinet Clearances

30" Min. to 36" Max. bottom of overhead Hood to cooking

surface (42" if hood

18" Min. contains combustible materials )

30" Wide Hood (Model #PH30QS)

 

 

 

 

 

 

 

 

 

} For 30" Ranges

48" for Island (Model #PHI48QS)

36" Wide Hood (Model #PH36QS)

} For 36" Ranges

 

 

 

48" for Island (Model #PHI48QS)

 

 

 

 

 

 

 

 

 

48" Wide Hood (Model #PH48QS)

} For 48" Ranges

60" for Island (Model #PHI60QS)

 

 

Min. Distance Between

Overhead

 

 

 

 

 

 

 

 

 

Cabinets of Combustible Material

 

 

 

 

 

 

 

 

 

 

30" Range – 30"

13" Max.

}

 

 

 

 

 

36" Range – 36"

 

 

 

 

 

Cabinet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48" Range – 48"

 

 

 

 

 

 

Depth

 

 

 

 

 

 

 

 

 

Range width

 

 

 

12" Min. to

 

 

 

30", 36" or 48"

 

 

 

 

 

 

 

 

 

 

 

 

combus-

 

 

 

 

 

 

 

 

walltible side

 

 

 

 

 

 

 

 

 

 

material , (both sides)

Cooking

Surface

CAUTION: See Figs. 2a, 2b and 2c. 42" Min. to combustible

material , from cooking surface

*35-3/8" Min. Range Height with Leveling Legs fully retracted *36-3/4" Max. Range Height with Leveling Legs fully extended

For Electrical and Gas Supply Zone, see Figures 3a, 3b and 3c. Zone size and position differ according to the model.

as defined in the “National Fuel Gas Code” (ANSI Z223.1, Latest Edition). *The range height is adjustable. The level of the range top must be at the same level or above the countertop level.