Thermador SGSX, SGSL Before Calling Service, Final Check, Product Data Plate

Models: SGSX SGSL SGS

1 36
Download 36 pages 9.51 Kb
Page 11
Image 11

Final Check

Check operation of electric igniters. Check flame

Yellow Flames:

characteristics. Flame should be blue with no yellow tip.

Further adjustment is required.

 

Yellow Tips on Outer Cones:

 

Normal for LP Gas.

 

Soft Blue Flames:

 

Normal for Natural Gas.

 

If the flame is completely or

 

mostly yellow, verify that the regulator is set for the

 

correct fuel. After adjustment, retest.

 

Some yellow streaking is normal during the initial start-

 

up. Allow unit to operate 4-5 minutes and re-evaluate

 

before making adjustments.

 

Figure 11: Checking Flame Characteristics

Service

Before Calling Service

If the ignitors do not spark or the “on” indicator lights do not glow, check the power source to see if a fuse has blown or if the circuit breaker has tripped.

Refer to the Warranty in the Use and Care Manual. See Use and Care manual for troubleshooting information.

Product Data Plate

The data plate shows the model and FD (product's unique identifier for customer service) number of your cooktop. It is located on the underside of the rough-in box, underneath the cooktop.

Data Plate

Figure 12: Data Plate Location

Keep your invoice or escrow papers for warranty validation if service is needed.

English 8

Page 11
Image 11
Thermador SGSX, SGSL installation manual Before Calling Service, Final Check, Product Data Plate