All installations and services must be performed by qualified service personnel.
NOTICE: This furnace has been shipped from the factory with a permanently lubricated circulating air blower motor. Any maintenance to this blower motor is to be performed only by a qualified heating contractor.
B. FILTER MAINTENANCE PROCEDURE
1.The return air filter provided with this unit is a
NOTICE: If the furnace is installed in a home or structure being remodeled, dust levels may be much higher than normal The filter must be inspected daily and cleaned as needed until dusty conditions have been eliminated. Any replacement motors not obtained through Thermo Products should be lubricated according to the motor name plate.
: This furnace is not to be used for temporary heating of buildings or structures under construction.
UPFLOW FURNACE (CHX1/CHB1/MHA1)
The filter rack or drop chute will be located between the return air plenum and the return air opening of the furnace (See Figure 3). Slide dirty filter out of the filter rack. Clean the filter by vacuuming, rinsing with tap water, hosing or dipping in an ordinary detergent solution. Replace the completely dry filter in the rack. The mesh side of the filter must be installed towards the furnace after cleaning.
COUNTERFLOW FURNACE (CDX1/CDB1/MDA1)
TURN OFF POWER TO FURNACE. The filter rack will be located on top of the furnace inside the return air duct using either a
12