C. SHUTDOWN PROCEDURE

All installations and services must be performed by qualified service personnel.

5.Turn gas control knob clockwise to “OFF” position. (For gas valves with a switch, move the switch to the “OFF” position).

6.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow Step B in the previous safety information. Go to the next step if you don’t smell gas.

7.Turn gas control knob counterclockwise to “ON” position. (For gas valves with a switch, move the switch to the “ON” position).

8.Replace front door.

9.Turn on electric power to the appliance.

10.Set thermostat to desired setting.

11.Follow the instructions “To Turn Off Gas To Appliance” and call a qualified heating contractor or gas supplier if the appliance will not operate.

C. SHUTDOWN PROCEDURE

TO TURN OFF GAS TO FURNACE:

1.Set the thermostat to lowest setting.

2.Turn off the electric power to the appliance if service is to be performed.

3.Remove front door.

4.Turn the knob on the combination valve to the full OFF position.

5.Replace front door.

IV. HOMEOWNER/USER MAINTENANCE INSTRUCTIONS (ROUTINE MAINTENANCE)

The following maintenance procedures should be performed by the homeowner/user during the heating season.

A. ANNUAL INSPECTIONManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background : Homeowners attempting maintenance other than that covered as homeowner/user maintenance may cause conditions which could result in personal injury or property damage.

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background : Shut off the power to the furnace before removing blower compartment door to avoid injury from moving parts.

A. ANNUAL INSPECTION

The homeowner must have this furnace professionally inspected at the beginning of each heating season by a qualified heating contractor to ensure proper operation.