All installations and services must be performed by qualified service personnel.
G. BURNER SPECIFICATIONS AND APPLICATIONS
RIELLO BURNER APPLICATION CHART
MODEL | OH5 2 STAGE | |
PART | ||
| ||
MTG. PLATE | 35750 | |
PART NO. | ||
| ||
MTG. PLATE |
| |
GASKET | 330088 | |
PART NO. |
| |
**NOZZLE | .70 X 45° W | |
SIZE |
| |
NOZZLE | 380702 | |
PART NO. | ||
| ||
OIL PUMP | 130 LOW | |
170 | ||
PRESSURE | ||
HIGH | ||
| ||
BURNER | ||
BURNER | 380695 | |
PART NO. | ||
|
* INSULATOR S = SLEEVE OR N = NONE
THE NOZZLE SIZE GIVES THE NOMINAL FLOWRATE, IN GPH, FOLLOWED BY THE SPRAY ANGLE, IN DEGREE’S, AND THE SPRAY PATTERN, EITHER “H” FOR HOLLOW CONE OR “S” FOR SOLID CONE. FOR EXAMPLE, A NOZZLE RATED AT 0.65 GPH @ 100 PSIG THAT PROVIDES AN 80° SPRAY ANGLE AND A HOLLOW SPRAY PATTERN WOULD BE ABBREVIATED IN THE TABLE AS “0.65 X 80°H”.
**NOTE: The reason the Riello burner nozzle sizes are smaller than the standard Thermo Pride burner nozzles is that
For more specific burner information, specifications or service information, reference the training manual enclosed
with each Riello burner or contact: Riello Corporation of America, 5 Pond Park Road
Hingham, Massachusetts 02043 (617)
2 STAGE FIRING RATES
| NOZZLE SIZE | INPUT RATE* | EFFECTIVE** |
HEATING | |||
Riello | (BTU/HR) | CAPACITY | |
HIGH FIRE |
| 106,250/170psi | 85,000 |
LOW FIRE | .70 X 45° W | 85,000/130psi | 74,000 |
*Based on #2 domestic heating fuel oil having heating value of 140,000 BTU per gallon.
**Based on thermal efficiency of
7