Thermo Products OH5-85DXE operation manual Stage Firing Rates

Models: OH5-85DXE

1 17
Download 17 pages 7.77 Kb
Page 10
Image 10
2 STAGE FIRING RATES

All installations and services must be performed by qualified service personnel.

G. BURNER SPECIFICATIONS AND APPLICATIONS

RIELLO BURNER APPLICATION CHART

MODEL

OH5 2 STAGE

PART

 

MTG. PLATE

35750

PART NO.

 

MTG. PLATE

 

GASKET

330088

PART NO.

 

**NOZZLE

.70 X 45° W

SIZE

 

NOZZLE

380702

PART NO.

 

OIL PUMP

130 LOW

170

PRESSURE

HIGH

 

BURNER

G-51

BURNER

380695

PART NO.

 

* INSULATOR S = SLEEVE OR N = NONE

THE NOZZLE SIZE GIVES THE NOMINAL FLOWRATE, IN GPH, FOLLOWED BY THE SPRAY ANGLE, IN DEGREE’S, AND THE SPRAY PATTERN, EITHER “H” FOR HOLLOW CONE OR “S” FOR SOLID CONE. FOR EXAMPLE, A NOZZLE RATED AT 0.65 GPH @ 100 PSIG THAT PROVIDES AN 80° SPRAY ANGLE AND A HOLLOW SPRAY PATTERN WOULD BE ABBREVIATED IN THE TABLE AS “0.65 X 80°H”.

**NOTE: The reason the Riello burner nozzle sizes are smaller than the standard Thermo Pride burner nozzles is that pre-set pump pressures are higher, therefore achieving the same firing rate with a smaller nozzle.

For more specific burner information, specifications or service information, reference the training manual enclosed

with each Riello burner or contact: Riello Corporation of America, 5 Pond Park Road

Hingham, Massachusetts 02043 (617) 749-8292

2 STAGE FIRING RATES

 

NOZZLE SIZE

INPUT RATE*

EFFECTIVE**

OH5-85DXE***

HEATING

Riello

(BTU/HR)

CAPACITY

HIGH FIRE

 

106,250/170psi

85,000

LOW FIRE

.70 X 45° W

85,000/130psi

74,000

*Based on #2 domestic heating fuel oil having heating value of 140,000 BTU per gallon.

**Based on thermal efficiency of 84%-85%.

7

Page 10
Image 10
Thermo Products OH5-85DXE operation manual Stage Firing Rates