8-3. FAULT IN SPECIFIC STATION ONLY

Find the cause according to the following table if the fault

lies with a specific station only, not with all stations.

 

CHECK-ITEM

CAUSE

Dialing can not

LMU Lamp is

Disconnection of both T & R-Lines.

be made at privacy

off.

Guard resistor 330 on LMU is

off mode.

 

burned out due to T & R-Lines

 

 

short.

Specific key does not operate.

Calling tone can not be heard.

Dialing tone can not be heard on dialing.

Sound from the

other party can not be heard.

Sound is not trans-

mitted to the other party.

On dialing, noise is heard by the called party.

Specific Lamp

T & R-Lines are shorted.

on

LMU is

 

brighter

than

 

normal.

 

 

LMU Lamp

is

Fault in the station.

on in normal.

(Replace PCB board.)

Replace the

Fault in key board switch or

station

and

matrix circuitry.

make sure that

Fault in the dial generator.

the station

(Replace PCB board.)

is not faulty.

 

Same sympton

Short or open in R-Line.

remains even

Fault in the demodulation cir-

if the station

cuitry on LMU.

is replaced.

(Check LM-380, MT-547.)

Becomes normal

Disconnection of R-Line or im-

if

the station

proper connection of the station

is replaced.

connector.

 

 

 

Fault in MT-547 on LMU.

 

 

 

Station fault.

Same sympton

Short or open in T-Line.

remains

even

Fault in the modulation cir-

the station

cuitry on LMU.

is replaced.

 

Becomes normal

Fault in MIC circuitry of the

if

the station

station. (Replace MIC or PCB)

is replaced.

 

Same sympton

One of T-Lines is disconnected.

remains

even

 

the

station is

 

replaced.

 

Becomes normal

Fault in MIC element.

if

the station

Fault in T-Line of the station.

is

replaced.

Low frequency oscillation of

 

 

 

MIC AMP. (Faulty bypass capaci-

 

 

 

tor)

-66-

Page 8
Image 8
TOA Electronics TOAEXES-5OOO manual Fault in Specific Station only