Table
Message | Causes | Corrective Actions |
|
|
|
Unsupported | Invalid memory | Ensure that the memory |
memory | configuration. | modules are installed in a |
configuration. | Memory modules are | valid configuration. |
DIMM mismatch | mismatched in the | See "General Memory |
across slots | specified slots. | Module Installation |
detected: |
| Guidelines" on page 119. |
x,x,... |
|
|
|
|
|
Unused memory | The memory configuration | Reconfigure the memory for |
detected. DIMM’s | is not optimal for | Memory Mirroring Mode, or |
installed in the | mirroring Mode. Modules | change the memory mode to |
following slot | in the specified slots are | Optimized or Sparing in the |
are not available | unused. | BIOS setup screen. See |
when in mirror |
| "System Memory" on |
mode: x,x,x |
| page 119. |
|
|
|
Unused memory | The memory configuration is | Reconfigure the memory for |
detected. DIMM’s | not optimal for Advanced | Advanced ECC Memory |
installed in the | ECC Memory Mode. | Mode, or change the |
following slot | Modules in the specified | memory mode to Optimized |
are not available | slots are unused. | or Sparing in the BIOS setup |
when in |
| screen. See "System |
advanced ECC |
| Memory" on page 119. |
mode: x,x,x |
|
|
|
|
|
Warning: A fatal | A fatal system error occurred | Check the SEL for |
error has caused | and caused the system to | information that was logged |
system reset! | reboot. | during the error. See the |
Please check the |
| applicable troubleshooting |
system event log! |
| section in "Troubleshooting |
|
| Your System" on page 145 for |
|
| any faulty components |
|
| specified in the SEL. |
52
About Your System