Table 1-2. LCD Status Messages (Optional) (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1114

Ambient Temp

Ambient temperature has

See "Troubleshooting

 

exceeds

a reached a point outside

System Cooling

 

allowed range.

of the allowed range.

Problems" on page 151.

E1116 Memory

Memory has exceeded

disabled, temp

allowable temperature and

above range.

has been disabled to

Power cycle

prevent damage to the

AC.

components.

Remove AC power to the system for 10 seconds and restart the system.

See "Troubleshooting System Cooling Problems" on page 151. If the problem persists, see "Getting Help" on page 167.

E1210 Motherboard

CMOS battery is missing

See "Troubleshooting the

battery

or the voltage is outside of

System Battery" on

failure. Check

the allowable range.

page 150.

battery.

 

 

E1211 RAID

RAID battery is either

Controller

missing, bad, or unable to

battery

recharge due to thermal

failure. Check

issues.

battery.

 

Reseat the RAID battery connector. See "Installing the RAID Battery" on page 118, and "Troubleshooting System Cooling Problems" on page 151.

E1216

3.3V Regulator

3.3V voltage regulator has

Remove and reseat the

 

failure.

failed.

PCIe expansion cards.

 

Reseat PCIe

 

If the problem persists,

 

cards.

 

see "Troubleshooting

 

 

 

Expansion Cards" on

 

 

 

page 159.

 

 

 

 

E1229

CPU # VCORE

Specified processor

Reseat the processor(s).

 

Regulator

VCORE voltage regulator

See "Troubleshooting the

 

failure.

has failed.

Microprocessors" on

 

Reseat CPU.

 

page 160.

If the problem persists, see "Getting Help" on page 167.

24

About Your System

Page 24
Image 24
Dell R410 E1114 Ambient Temp, Exceeds, Allowed range, E1116 Memory, Disabled, temp, Above range, Power cycle, Battery