Table
Code | Text | Causes | Corrective Actions |
|
|
|
|
E2113 | Mem mirror OFF | The system BIOS has | Remove AC power to the |
| on DIMM ## & | disabled memory | system for 10 seconds and |
| ##. Power | mirroring because it has | restart the system. |
| cycle AC | determined one half of the | If the problem persists, |
|
| mirror has had too many | see "Troubleshooting |
|
| errors. "## & ##" | |
|
| System Memory" on | |
|
| represents the | |
|
| page 152. | |
|
| ||
|
|
| |
|
| implicated by the BIOS. |
|
|
|
|
|
I1910 | Intrusion | System cover has been | Information only. |
| detected. | removed. |
|
| Check chassis |
|
|
| cover. |
|
|
I1911 LCD Log Full. LCD overflow message. Check SEL to A maximum of ten error
review all messages can display
Errors. sequentially on the LCD. The eleventh message instructs the user to check the SEL for details on the events.
Check the SEL for details on the events.
Remove AC power to the system for 10 seconds or clear the SEL.
I1912 | SEL full. | The SEL is full of events | Check the SEL for details |
| Review & clear | and is unable to log any | on the events, then clear |
| log. | more. | the SEL. |
|
|
|
|
I1920 | iDRAC6 Upgrade | optional iDRAC6 has | Information only. |
| Successful | been upgraded |
|
|
| successfully. |
|
W1228 RAID | Warns predictively that |
Controller | the RAID battery has |
battery | less than 24 hours of |
capacity < | charge left. |
24hr. |
|
Allow RAID battery to charge to greater than 24 hours of sustained charge.
If problem persists, replace RAID battery. See "Installing the RAID Battery" on page 118."
About Your System
35