Table 1-2. LCD Status Messages (Optional) (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E2113

Mem mirror OFF

The system BIOS has

Remove AC power to the

 

on DIMM ## &

disabled memory

system for 10 seconds and

 

##. Power

mirroring because it has

restart the system.

 

cycle AC

determined one half of the

If the problem persists,

 

 

mirror has had too many

see "Troubleshooting

 

 

errors. "## & ##"

 

 

System Memory" on

 

 

represents the

 

 

page 152.

 

 

memory-module pair

 

 

 

 

 

implicated by the BIOS.

 

 

 

 

 

I1910

Intrusion

System cover has been

Information only.

 

detected.

removed.

 

 

Check chassis

 

 

 

cover.

 

 

I1911 LCD Log Full. LCD overflow message. Check SEL to A maximum of ten error

review all messages can display

Errors. sequentially on the LCD. The eleventh message instructs the user to check the SEL for details on the events.

Check the SEL for details on the events.

Remove AC power to the system for 10 seconds or clear the SEL.

I1912

SEL full.

The SEL is full of events

Check the SEL for details

 

Review & clear

and is unable to log any

on the events, then clear

 

log.

more.

the SEL.

 

 

 

 

I1920

iDRAC6 Upgrade

optional iDRAC6 has

Information only.

 

Successful

been upgraded

 

 

 

successfully.

 

W1228 RAID

Warns predictively that

Controller

the RAID battery has

battery

less than 24 hours of

capacity <

charge left.

24hr.

 

Allow RAID battery to charge to greater than 24 hours of sustained charge.

If problem persists, replace RAID battery. See "Installing the RAID Battery" on page 118."

About Your System

35

Page 35
Image 35
Dell R410 E2113 Mem mirror OFF, ##. Power, I1910 Intrusion, Check chassis Cover, I1912 SEL full, Log, I1920 IDRAC6 Upgrade