Table 1-3. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

DIMM

Invalid memory

Ensure that the memory

configuration on

configuration on a

modules are installed in a

each CPU should

dual-processor system.

valid configuration.

match.

The memory module

See "General Memory

 

configuration for each

Module Installation

 

processor must be identical.

Guidelines" on page 119.

 

 

 

Embedded NICx and

The OS NIC interface is set

Check the system

NICy:

in BIOS. The Management

management software or the

OS NIC=<ENABLED

Shared NIC interface is set

System Setup program for

DISABLED>,

in management tools.

NIC settings. If a problem is

Management

 

indicated, see

Shared NIC=

 

"Troubleshooting a NIC" on

<ENABLED

 

page 147.

DISABLED>

 

 

Error 8602 - Auxiliary Device Failure. Verify that mouse and keyboard are securely attached to correct connectors.

Mouse or keyboard cable is

Reseat the mouse or

loose or improperly

keyboard cable.

connected.

 

Defective mouse or keyboard. Ensure that the mouse or keyboard is operational. See "Troubleshooting a USB Device" on page 146.

Gate A20 failure

Faulty keyboard controller;

See "Getting Help" on

 

faulty system board.

page 167.

 

 

 

Invalid

An invalid system

Run the System Setup

configuration

configuration caused a

program and review the

information -

system halt.

current settings. See "Using

please run SETUP

 

the System Setup Program

program.

 

and UEFI Boot Manager" on

 

 

page 57.

About Your System

43

Page 43
Image 43
Dell R410 Configuration on, Each CPU should, Match, Embedded NICx, NICy, Management, Shared NIC=, Gate A20 failure