Table 1-3. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Alert! iDRAC6 not

The optional iDRAC6

Remove AC power to the

responding.

has hung.

system for 10 seconds and

Power required

The optional iDRAC6 was

restart the system.

may exceed PSU

 

remotely reset while system

 

wattage.

 

was booting.

 

 

 

Alert!

After AC recovery, the

 

Continuing

 

optional iDRAC6 takes

 

system boot

 

longer than normal to boot.

 

accepts the risk

 

 

 

that system may

 

 

power down

 

 

without warning.

 

 

Alert! Node

The memory configuration

Interleaving

does not support node

disabled! Memory

interleaving, or the

configuration

configuration has changed

does not support

(for example, a memory

Node

module has failed) so that

Interleaving.

node interleaving cannot be

 

supported. The system will

 

still run, but without node

 

interleaving.

Ensure that the memory modules are installed in a configuration that supports node interleaving. Check other system messages for additional information for possible causes. For memory configuration information, see "General Memory Module Installation Guidelines" on page 119.

If the problem persists,

see "Troubleshooting System Memory" on page 152.