Table
Message | Causes | Corrective Actions |
|
|
|
Alert! iDRAC6 not | The optional iDRAC6 | Remove AC power to the |
responding. | has hung. | system for 10 seconds and |
Power required | The optional iDRAC6 was | restart the system. |
may exceed PSU |
| |
remotely reset while system |
| |
wattage. |
| |
was booting. |
| |
|
| |
Alert! | After AC recovery, the |
|
Continuing |
| |
optional iDRAC6 takes |
| |
system boot |
| |
longer than normal to boot. |
| |
accepts the risk |
| |
|
| |
that system may |
|
|
power down |
|
|
without warning. |
|
|
Alert! Node | The memory configuration |
Interleaving | does not support node |
disabled! Memory | interleaving, or the |
configuration | configuration has changed |
does not support | (for example, a memory |
Node | module has failed) so that |
Interleaving. | node interleaving cannot be |
| supported. The system will |
| still run, but without node |
| interleaving. |
Ensure that the memory modules are installed in a configuration that supports node interleaving. Check other system messages for additional information for possible causes. For memory configuration information, see "General Memory Module Installation Guidelines" on page 119.
If the problem persists,
see "Troubleshooting System Memory" on page 152.
About Your System
39