Table 1-3. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Alert! Power

The system configuration

If any system components

required exceeds

of processor(s),

were just upgraded,

PSU wattage.

memory modules,

return the system to the

Check PSU and

and expansion cards may

previous configuration.

system

not be supported by the

If the system boots without

configuration.

power supplies.

this warning, then the

Alert!

 

replaced component(s) are

 

not supported with this

Continuing

 

 

power supply. If Energy

system boot

 

 

Smart power supplies are

accepts the risk

 

 

installed, replace them with

that system may

 

 

High Output power supplies

power down

 

 

to use the components.

without warning.

 

 

See "Power Supplies" on

 

 

 

 

page 92.

Alert! Redundant

Memory Sparing or Memory

memory disabled!

Mirroring was enabled in the

Memory

system setup program, but

configuration

the current configuration

does not support

does not support redundant

redundant

memory. A memory module

memory.

may be faulty.

Check the memory modules for failure. See "Troubleshooting System Memory" on page 152. Reset the memory setting, if appropriate. See "Using the System Setup Program and UEFI Boot Manager" on page 57.

Alert! System

An error caused the system to

Check other system

fatal error

reboot.

messages for additional

during previous

 

information for possible

boot.

 

causes.