Table
Code | Text | Causes | Corrective Actions |
|
|
|
|
E1313 | Fan redundancy | The system is no longer | Check LCD for |
| lost. Check | fan redundant. Another | additional scrolling |
| fans. | fan failure would put the | messages. See |
|
| system at risk of | "Troubleshooting a Fan" |
|
| on page 152. |
E1410 Internal Error | Specified processor has an |
detected. | internal error. The error |
Check "FRU X". may or may not have been caused by the processor.
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists, see "Getting Help" on page 167.
E1414 | CPU # temp | Specified processor is out | Ensure that the processor |
| exceeding | of acceptable temperature | heat sinks are properly |
| range. Check | range. | installed. See |
| CPU heatsink. |
| "Troubleshooting the |
|
|
| Microprocessors" on |
|
|
| page 160 and |
|
|
| "Troubleshooting System |
|
|
| Cooling Problems" on |
|
|
| page 151. |
|
|
|
|
E1418 | CPU # not | Specified processor is | Ensure that the specified |
| detected. | missing or bad, and the | microprocessor is |
| Check CPU is | system is in an | properly installed. See |
| seated | unsupported | "Troubleshooting the |
| properly. | configuration. | Microprocessors" on |
|
|
| page 160. |
|
|
|
|
E141C | Unsupported | Processors are in an | Ensure that your |
| CPU | unsupported | processors match and |
| configuration. configuration. | conform to the type | |
| Check CPU or |
| described in the processor |
| BIOS revision. |
| technical specifications |
|
|
| outlined in your system’s |
|
|
| Getting Started Guide. |
26