Table 1-2. LCD Status Messages (Optional) (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1313

Fan redundancy

The system is no longer

Check LCD for

 

lost. Check

fan redundant. Another

additional scrolling

 

fans.

fan failure would put the

messages. See

 

 

system at risk of

"Troubleshooting a Fan"

 

 

over-heating.

on page 152.

E1410 Internal Error

Specified processor has an

detected.

internal error. The error

Check "FRU X". may or may not have been caused by the processor.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists, see "Getting Help" on page 167.

E1414

CPU # temp

Specified processor is out

Ensure that the processor

 

exceeding

of acceptable temperature

heat sinks are properly

 

range. Check

range.

installed. See

 

CPU heatsink.

 

"Troubleshooting the

 

 

 

Microprocessors" on

 

 

 

page 160 and

 

 

 

"Troubleshooting System

 

 

 

Cooling Problems" on

 

 

 

page 151.

 

 

 

 

E1418

CPU # not

Specified processor is

Ensure that the specified

 

detected.

missing or bad, and the

microprocessor is

 

Check CPU is

system is in an

properly installed. See

 

seated

unsupported

"Troubleshooting the

 

properly.

configuration.

Microprocessors" on

 

 

 

page 160.

 

 

 

 

E141C

Unsupported

Processors are in an

Ensure that your

 

CPU

unsupported

processors match and

 

configuration. configuration.

conform to the type

 

Check CPU or

 

described in the processor

 

BIOS revision.

 

technical specifications

 

 

 

outlined in your system’s

 

 

 

Getting Started Guide.