Table
Message | Causes | Corrective Actions |
|
|
|
Unable to launch | System halted after F10 | Restart the system and |
System Services | keystroke because System | update the Unified Server |
image. System | Services image is either | Configurator repository to |
halted! | corrupted in the system | the latest software to restore |
| firmware or has been lost due | full functionality. See the |
| to system board replacement. Unified Server | |
| The optional iDRAC6 | Configuration user |
| documentation for | |
| Enterprise card flash memory | |
| or BMC SPI flash may be | more information. |
|
| |
| corrupted. | Restore the flash memory |
|
| using the latest version on |
|
| support.dell.com. See the |
|
| Integrated Dell™ Remote |
|
| Access Controller 6 |
|
| (iDRAC6) User Guide for |
|
| instructions on performing a |
|
| field replacement of the |
|
| flash memory. |
|
|
|
Unexpected | Improperly seated memory | Reseat the memory modules. |
interrupt in | modules or faulty | See "Troubleshooting |
protected mode | keyboard/mouse | System Memory" on |
| controller chip. | page 152. If the problem |
|
| persists, see "Getting Help" |
|
| on page 167. |
|
|
|
Unsupported CPU | Processor(s) is not supported | Install a supported processor |
combination | by the system. | or processor combination. |
Unsupported CPU |
| See "Processors" on |
| page 126. | |
stepping |
| |
|
| |
detected |
|
|
|
|
|
Unsupported DIMM | Invalid memory | Ensure that the memory |
detected. The | configuration. The system | modules are installed in a |
following DIMM | will run but with the | valid configuration. See |
has been | specified memory module | "General Memory Module |
disabled: x | disabled. | Installation Guidelines" on |
|
| page 119. |
About Your System