Table 1-3. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Warning: Control

The control panel is not

Install the control panel, or

Panel is not

installed or has a faulty cable

check the cable connections

installed.

connection.

between the display module,

 

 

the control panel board,

 

 

and the system board.

 

 

See "Control Panel

 

 

Assembly-LED/LCD

 

 

(Service-Only Procedure)

 

 

(Optional)" on page 132.

 

 

 

Warning! No micro

Micro code update failed.

Update the BIOS firmware.

code update

 

See "Getting Help" on

loaded for

 

page 167.

processor n

 

 

Warning! Power

The system configuration of

required exceeds

processor(s), memory

PSU wattage.

modules, and expansion

Check PSU and

cards may not be supported

system

by the power supplies.

configuration.

 

Warning!

 

Performance

 

degraded. CPU and

 

memory set to

 

minimum

 

frequencies to

 

meet PSU wattage.

 

System will

 

reboot.

 

If any system components were just upgraded, return the system to the previous configuration. If the system boots without this warning, then the replaced component(s) are not supported with this power supply. If Energy Smart power supplies are installed, replace them with the High Output power supplies to use the components. See "Power Supplies" on page 92.

Warning! PSU

A High Output power supply

mismatch. PSU

and an Energy Smart power

redundancy lost.

supply are installed in the

Check PSU.

system at the same time.

Install two High Output or two Energy Smart power supplies in the system.

You can also run the system on one power supply until you can obtain two power supplies of the same type. See "Troubleshooting Power Supplies" on page 151.