Cisco Intrusion Prevention System Sensor CLI Configuration Guide for IPS 7.2
OL-29168-01
AppendixC Troubleshooting
Analysis Engine Not Responding
Analysis Engine Not Responding
Error Message Output from show statistics analysis-engine
Error: getAnalysisEngineStatistics : ct-sensorApp.424 not responding, please
check system processes - The connect to the specified Io::ClientPipe failed.
Error Message Output from show statistics anomaly-detection
Error: getAnomalyDetectionStatistics : ct-sensorApp.424 not responding, please
check system processes - The connect to the specified Io::ClientPipe failed.
Error Message Output from show statistics denied-attackers
Error: getDeniedAttackersStatistics : ct-sensorApp.424 not responding, please
check system processes - The connect to the specified Io::ClientPipe failed.
Possible Cause
These error messages appear when you run the show tech support command and the
Analysis Engine is not running.
Recommended Action
Verify the Analysis Engine is running and monitor it to see if the issue is
resolved.
To verify the Analysis Engine is running and to monitor the issue, follow these steps:
Step 1
Log in to the sensor.
Step 2
Verify that the Analysis Engine is not running, Check to see if the Analysis Engine reads
Not Running
.
sensor# show version
-----
MainApp V-2013_04_10_11_00_7_2_0_14 (Release) 2013-04-10T11:05:55-0500
Running
AnalysisEngine V-2013_04_10_11_00_7_2_0_14 (Release) 2013-04-10T11:05:55-0500
Not Running
CollaborationApp V-2013_04_10_11_00_7_2_0_14 (Release) 2013-04-10T11:05:55-0500
Running
CLI V-2013_04_10_11_00_7_2_0_14 (Release) 2013-04-10T11:05:55-0500
Step 3
Enter
show tech-support
and save the output.
Step 4
Reboot the sensor.
Step 5
Enter
show version
after the sensor has stabilized to see if the issue is resolved.
Step 6
If the Analysis Engine still reads
Not Running
, contact TAC with the original show tech support
command output.