C-57
Cisco Intrusion Prevention System Sensor CLI Configuration Guide for IPS 7.2
OL-29168-01
Appendix C Troubleshooting
Troubleshooting the ASA5500-X IPS SSP

Time Synchronization on IME and the Sensor

Symptom
The IME displays
No Data Available
on the Events dashboard. A historical query does not
return any events; however, events are coming in to the IME and they appear in the real-time event
viewer.
Possible Cause
The time is not synchronized between the sensor and the IME local server. The IME
dashboards use a time relative to the IME local time. If these times are not synchronized, the query
does not return any results. When you add a sensor to the IME, it checks for the time synchronization
and warns you to correct it if is in wrong. The IME also displays a clock warning in Home >
Devices > Device List to warn you about problems with synchronization.
Recommended Action
Change the time settings on the sensor or the IME local server. In most cases,
the time change is required for the sensor because it is configured with the incorrect or default time.
For More Information
For more information on time and the sensor, see Time Sources and the Sensor, page C-15.
For the procedure for changing the time on the sensor, see Corr ecting Time on the Sensor,
page C-16.

Not Supported Error Message

Symptom
The IME displays
Not Supported
in the device list table and in some gadgets, and no data is
included.
Possible Cause
Click Details to see an explanation for this message. The IME needs IPS 6.1 or later
to obtain certain information. The IME still operates with event monitoring and reporting for IPS 5.0
and later and specific IOS IPS versions, but some functions, such as health information and
integrated configuration, are not available.
Recommended Action
Upgrade to IPS 6.1 or later.
Troubleshooting the ASA 5500-X IPS SSP
Note
Before troubleshooting the ASA5500-X IPS SSP, check the Caveats section of the Readme for the
software version installed on your sensor to see if you are dealing with a kn own issue.
This section contains troubleshooting information specific to the ASA 550 0-X IPS SSP, and contains the
following topics:
Health and Status Information, pageC-58
Failover Scenerios, pageC-65
The ASA 5500-X IPS SSP and the Normalizer Engine, page C-66
The ASA 5500-X IPS SSP and Memory Usage, page C-67