Top Innovations SP-350 manual Removing Mineral Buildup, P.11

Models: SP-350

1 13
Download 13 pages 51.81 Kb
Page 12
Image 12
Removing Mineral Buildup

Removing Mineral Buildup

One common problem with steamers is mineral buildup caused by the high mineral content in many municipal water supplies. Mineral residue inside of the internal pipes and heater can cause intermittent steaming or in severe cases no steaming at all.

The best way to avoid this is to use demineralized or distilled water in the unit. The procedure below can be used to clear mineral buildup. If you are unable to use de-mineralized or distilled water we recommend you use this procedure monthly to help avoid mineral buildup.

1. Turn the unit off and unplug the power cord.

2.Unscrew and remove the hose from the hose connector on the top of the unit.

3.Remove the pole from the unit.

4.Remove the water tank from the main unit and drain any water in the unit.

5. Make a mixture of 50% vinegar and 50% water. In most cases 1 cup of this mixture will be sufficient.

6.Slowly pour the water-vinegar mixture into the hose connector.

a.If the internal piping is only partially blocked by mineral buildup, the water- vinegar mixture will soon start flowing out of the water intake hole. If this happens proceed to step 8.

b.If the internal piping is completely blocked, continue to pour the mixture into the hose connector till full.

7 . Pour the water-vinegar mixture into the water intake hole until full.

8.Let stand for 40 minutes.

9.Drain the water using the drain plug.

10.Pour clean water though the hose base and water intake hole until the vinegar smell dissipates.

11. Reassemble the unit and operate normally.

If the procedure above does not return the unit to normal operation, the unit may need servicing.

P.11

Page 12
Image 12
Top Innovations SP-350 manual Removing Mineral Buildup, P.11