Topcom 1850 Operation, 6.1 On/off, Empty water tank, Humidity level control, Warm mist, Ionizer

Models: 1850

1 92
Download 92 pages 41.32 Kb
Page 5
Image 5

TOPCOM Multifunctional Humidifier 1850

It is recommended to use soft (distilled - low-mineral) water to minimize lime scale on the transducer.

Do not remove the water tank when the humidifier is connected to the main power. When you remove the water tank after usage, there will still be water in the water flume. Remove the water from the tank and flume when it is not used for a long period.

Clean the water box, spray mouth and water flume if the humidifier is not used for a long period. Do not position the humidifier near heat sources or direct sunlight.

Do not aim the fume dispenser to furniture, electronic equipment or baby beds.

6Operation

6.1On/off

Press the on/off button k on the unit on the remote control to activate the humidifier. The display lights up and, after a few seconds, the ambient humidity is displayed.

Press the on/off button k again to deactivate the humidifier.

6.2Empty water tank

If the water tank is empty, the empty water tank indication e is displayed.

6.3Humidity level control

Press the humidity level button h to increase the humidity setting from 40% to 80%. After flashing for 5 seconds, the LCD display shows the level of ambient humidity b .

When the moisture level reaches the pre-set value, the humidifier automatically stops for five minutes in order to test the humidity in the air.

Instead of selecting the humidity level 40% to 80%, you can also select ‘- -’for continuous operation.

6.4Warm mist

If the water gets stagnant, it will spray the stagnant water, and any bacteria it contains, into your home. This is why it is important to clean the tank regularly and refill it with clean water when you haven't been running it.

To avoid that bacteria are sprayed around in your room, the Multifunctional Humidifier 1850 can pre-heat the water before it is sprayed.

It will take several minutes before the mist will feel tepid. The mist will never feel hot!

When activating the humidifier, the warm mist function is automatically on. The warm mist icon d

is displayed.

• To deactivate the warm mist, press the warm mist button i .

6.5Mist intensity

Press the mist intensity button g to change the generated amount of mist. The display will indicate the mist intensity n .

6.6Ionizer

The air ioniser is a device which uses high voltage to ionise, or electrically negative charge, molecules of air. Negative ions help freshen and purify bad particles in the air, which are causing allergens such as pollen, mold spores, dust, and animal dander floating in the air . They help to lift mood, alleviate depression and seasonal affective disorder and promote a sense of well-being.

When the Humidifier is on:

 

 

Press the Ionizer button

f

to start the ioniser. The ionizer icons blink on the screen.

Press the Ionizer button

f

again to stop the ioniser.

ENGLISH

5

Page 5
Image 5
Topcom 1850 Operation, 6.1 On/off, Empty water tank, Humidity level control, Warm mist, Mist intensity, Ionizer, English