8 LAYOUT
8-14
5Enter instrument height in the same way. [F1]
Enter
INS.HT
[F4]
6Enter the known point A number. *3) [F1]
Enter PT#
[F4]
7Enter reector height. [F1]
Enter R.HT
[F4]
8Collimate the known point A, and press the
[F1](ANG) or [F2](DIST) key.
Example:[F2](DIST)
Distance measuring starts.
Known point B entering display will be shown.
Collimate A
[F2]
9Same as procedure 6 to 8 proceed to the known
point B.
When two points have been measured by the
[F2](DIST) key, the RESIDUAL ERROR will be
calculated. *4)
10 Select GRID FACTOR for calculation of
RESIDUAL ERROR by pressing [F1] or [F2]
key. *5)
Example: [F1]
[F1]
11 Press the [F1](NEXT) key to measure other points.
Maximum seven points can be measured. [F1]
12 Same as procedure 6 to 8 proceed to the known
point C.
NO01#
PT#:
INPUT LIST NEZ ENTER
REFLECTOR HEIGHT
INPUT
R.HT : 0.000 m
INPUT ––– ––– ENTER
REFLECTOR HEIGHT
INPUT
R.HT : 1.235 m
ANG DIST NP/P ---
HR: 123°40'20"
HD*[n] < m
VD: m
> Measuring...
< complete >
NO02#
PT#:
INPUT LIST NEZ ENTER
SELECT GRID FACTOR
F1:USE LAST DATA
F2:CALC MEAS.DATA
RESIDUAL ERROR
dHD= 0.015 m
dZ = 0.005 m
NEXT ––– G.F. CALC
NO03#
PT#:
INPUT LIST NEZ ENTER
HR: 123°40'20"
HD*[n] < m
VD: m
> Measuring...
< complete >
HR: 123°40'20"
HD: 123.456 m
VD: 1.234 m
NEXT ––– ––– CALC