9 MEMORY MANAGER MODE
9-16
9.8 InitializationThis mode is used to initialize the internal memory.
Following data can be initialized.
FILE DATA :All files of measuring data and coordinate data
PCODE DATA: PCODE LIST
ALL DATA: FILE DATA and PCODE DATA
Note that the following data are not initialized even if initialization is executed.
: Coordinates of the instrument, Instrument height and Reflector height.
Example Initialization: ALL DATA ( FILE data and PCODE data)
Operating procedure Operation Display
1Press the [F3](MEMORY MGR.) key from the
menu 1/3. [F3]
2Press the [F4](P
↓
) key twice. [F4]
[F4]
3Press the [F2](INITIALIZE) key. [F2]
4Select the data to initialize by pressing one of the
[F1] to [F3] key.
Example : [F3](ALL DATA)
[F3]
5Confirm the erase data, press the [F4](YES) key.
Initializing will start.
The display returns to menu.
[F4]
MEMORY MGR. 1/3
F1:FILE STATUS
F2:SEARCH
F3:FILE MAINTAN. P
↓
MEMORY MGR. 3/3
F1:DATA TRANSFER
F2:INITIALIZE
P
↓
INITIALIZE
F1:FILE AREA
F2:PCODE LIST
F3:ALL DATA
INITIALIZE DATA
ERASE ALL DATA !
>OK ? [NO][YES]
INITIALIZE DATA
<Initializing!>
MEMORY MGR. 3/3
F1:DATA TRANSFER
F2:INITIALIZE
P
↓