Toro TDC-100/200 manual Manual Watering, Manual M-Manual Sta# 01-12 Simult Press Start to water

Models: TDC-100/200

1 20
Download 20 pages 33.32 Kb
Page 14
Image 14

Manual Watering

The Manual Watering functions are used for additional watering if the irrigation program is not sufficient. They can also be used to troubleshoot each station for proper operation. Pressing the Manual Watering Key will access three manual irrigation functions; Multi-Manual, Syringe and Program.

M-Manual- Select M-Manual to activate a station or group of stations with a specified runtime.

Multi-Manual Station Activation Directions

Manual station activation example: Activate stations 1–12 with a runtime of 5 minutes each and limit watering to 3 stations simultaneously.

Note: The Multi-Manual function is limited to the maximum simultaneous station settings of the controller. In cases where a program is running and a multi-manual activated, the controller will activate all stations specified in the multi-manual in addition to the currently activated stations. Thus, the multi-manual will allow the controller to exceed the maximum simultaneous station settings.

1. Press the Manual Watering Key .

2.

The cursor should be located in the Manual field, use the Input Dial

 

to select M-Manual.

 

 

 

3.

Press the Down Arrow

to advance the cursor to the Sta#: field. Use the Input Dial

 

 

to select

 

the correct value of the first station being irrigated. For this example, select station 01.

4.Press the Right Arrow to advance the cursor to the next value. This value will indicate the last station of the range. If irrigating only one station, this value should be the same as the first value. For this example, select station 12.

5.Press the Right Arrow to advance the cursor to the next entry field. This entry field will indicate the

runtime in hours, minutes and seconds (HH:MM:SS). Use the Input Dial

 

and the Right Arrow Key

 

to select the appropriate runtime value. For this example, set the value to 00:05.

6.Press the Down Arrow to advance the cursor to the next entry field. Notice that a new Station: line was created. Fill this line only if irrigating multiple ranges of stations, otherwise, leave this line blank.

7. Press the Down Arrow

to advance the cursor to the Simult: field. Use the Input Dial

 

to select

 

the maximum simultaneous irrigating stations. For this example, set the value to 03.

8.Once finished, press the Start Key to activate or press the Home Key to cancel and revert back to the default display.

Note: Pressing the Home Key will save the entered values. When finished, the display should read:

Manual: M-Manual

Sta#: 01-12 00:05

Sta#: ----- --:--

Simult: 03

Press START to water

14

Page 14
Image 14
Toro TDC-100/200 manual Manual Watering, Manual M-Manual Sta# 01-12 Simult Press Start to water