Power-Up Diagnostics
Upon
TDC–100/200 System
Booting
The
When completed, information will be displayed momentarily on the screen for five seconds. This status information can not be edited. The information is as follows:
Line 1:
Line 2: Detect: [xx stations, yy sensors] (xx = number of stations detected, yy = number of sensors detected)
Line 3: Last Power Downtime Date and Time
Example:
Rev: D1.21, 04/25/06
Detect:200sta, 00sen
PD 05/24/06 10:51:20
The default Home display will follow after the diagnostic display has
Home display example:
Mon 08/07/06 10:50am
Sec: 45
Day Change: 12:00am
Home Key
Pressing the Home Key will revert to the default display. When editing irrigation programs, Station or System settings, pressing the Home Key will save any setting modifications and return the user to the Home display.
Home display example:
Mon 08/07/06 10:50am Sec: 45
Day Change: 12:00am
Mon 08/07/06 11:15am
Sec: 50
Rain
Day Change: 12:00am
Rain detected indicator for rain sensor equipped Decoder systems
The Day Change line will display the next program start time (Next Start: HH:MM) if the current day is an active watering day. If the controller is running a program, the Day Change line will display Running XX programs to indicate the number of active programs.
The following example display has two programs running with two stations manually activated, the display will read:
Wed 08/09/06 06:50am Sec: 32
Running 02 Programs
P01 Sta01 %00:05:00
P01 Sta02 00:05:00
P01 Sta03D 00:05:00
P02 Sta10P 00:10:00
Man Sta18S 00:05:00 Man Sta19S 00:10:00
(The “%” symbol before the runtime indicates that station 1 is percent adjusted.) (P01 indicates Program 01 is currently active)
(The “D” symbol after the station number indicates that station 3 is disabled.) (The “P” symbol after the station number indicates that program 02 is paused.)
(“Man” indicates Manual Watering is currently active)
(The “S” symbol after the station number indicates that program 02 is stacked.)
Note: Program stacking occurs when the controller is running a program where the maximum simultaneous station limit is surpassed. Additional scheduled programs will be stacked (delayed) until an available station can be activated.
7