External HD/VD Input Phase Specifications
External HD rising edge
100100
External HD
Unit : Clock 1Clk=40.74nsec
Center
The phase relationship of the external HD and VD should correspond to the center phase (i.e., the external HD falling edge) as illustrated in the above diagram.
External VD falling edge:
Please input within about 100 clock cycles of the standard center phase.
Note that V sync of the video is output with a delay of about 1H from the external VD at the time of
In the normal mode:
Continuously with the HD period of 31.78 ∝s and VD period of 16.68 ms (partial scanning ON: 5.56ms).
Phase timing is as illustrated in the above diagram (with only the falling edge applicable).
In the reset-restart/external trigger mode:
Continuously with the HD period of 31.78 ∝s. VD (reset) is at an arbitrary timing with the phase of HD being within the standard of the above diagram.
16