6SYNC

When an external sync signal is input, the display changes from INT (internal sync) to EXT.(external sync) automatically.

INT EXT

61INT screen

-- 6 SYNC --

<FILE A>

MODEINT

62Changing EXT. setting

Move up and down

 

Select the desired

by pushing

 

value by pushing

MENU UP,DOWN

 

DATA UP,DOWN

--6 SYNC -- <FILE A>

MODE

EXT

H PHASE

0

Sync system display

H PHASE -650 to 650

(a) Adjusting horizontal phase

Move the “ ” to H PHASE by pushing [MENU UP], [MENU DOWN] buttons.

Select the desired value of horizontal phase by pushing [DATA UP], [DATA DOWN] buttons.

DATA UP

650 0 650

DATA DOWN

*If the phase difference is large, continuously pressing on the [DATA UP]/[DATA DOWN] button will make the setting shift by tens.