Toshiba IK-TF2 instruction manual Mode EXT Trig 1PULSE SNR Trig Pulse Exposure, 16ms

Models: IK-TF2

1 32
Download 32 pages 22.13 Kb
Page 16
Image 16

￿1￿3￿ Changing each setting in EXT TRIG mode

The EXT TRIG has three modes; 1PULSE SNR, 1PULSE SR, 2PULSE.

First set the “￿” to MODE and select EXT TRIG, then set the “￿” to EXT TRIG and select the desired EXT TRIG mode.

￿1￿3￿1￿ Changing each setting in 1PULSE SNR mode

Move up and down

 

Set by pushing

 

By pushing

 

DATA UP,DOWN

 

MENU UP,DOWN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-- 1 SHUTTER --

￿MODE

 

EXT TRIG

EXT TRIG

 

1PULSE SNR

TRIG PULSE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXPOSURE

 

16ms

 

 

 

 

 

 

 

 

 

￿Shutter mode MANUAL, SS, EXT TRIG

￿EXT TRIG mode

1PULSE SNR, 1PULSE SR, 2PULSE

￿Input trigger pulse setting at 1PULSE SNR and 1PULSE SR

￿ The rising edge

￿ The falling edge

￿ Front and back edges of pulse

￿ Front and back edges of pulse ￿Exposure time setting at 1PULSE SNR and 1PULSE SR

￿ 0.06ms

0.4ms

1ms

16ms

￿ 0.02ms step

0.1ms step

 

1ms step

< MODE = EXT TRIG EXT TRIG = 1PULSE SNR>

(a)Changing inputting trigger pulse setting

￿Set the “￿” to TRIG PULSE by pushing [MENU UP], [MENU DOWN] buttons.

￿ Select either , ,

,

by pushing [DATA UP], [DATA DOWN] buttons.

*This setting is only valid in the 1PULSE mode (1PULSE SNR and 1PULSE SR). To make the trigger pulse setting when using the 2PULSE mode, first set the EXT TRIG mode to 2PULSE, then make the settings with the TRIG PULSE items.

(b)Changing 1PULSE exposure time setting

￿Set the “￿” to EXPOSURE by pushing [MENU UP], [MENU DOWN] buttons.

￿Set the exposure time by pushing [DATA UP], [DATA DOWN] buttons.

* When or is selected, EXPOSURE cannot be set. (EXPOSURE setting turns OFF.)

Exposure time is automatically controlled by the trigger pulse width.

- 16 -