ISOLATED-REDUNDANT UPS SYSTEMS

Toshiba’s Isolated Redundant UPS System offers the ultimate in reliability, maintainability and availability. This UPS system delivers maximum design flexibility that is unmatched by any other configured UPS design.

An isolated-redundant UPS system allows the user to never have critical loads exposed or fed from the utility source, even during UPS module failures or UPS module maintenance. The principal behind this system is that the critical load is divided into separated, isolated segments, which means that the failure of one segment cannot affect the other load segments. Reliability is maximized and common- mode failure is minimized!

Each load segment can be a single, modular UPS system. If a UPS load segment failure causes a transfer to static bypass, the static bypass source is another standby UPS system.

Isolated-Redundant UPS Module

Oversized Redundant UPS Module

In isolated redundant systems, the standby UPS system is always ready to support the critical load since it is on-line and keeps its own battery plant charged. A key requirement of this system is

that the standby UPS system must accept a 100% step load with minimal transient voltage. Toshiba’s design can handle 100% step load without using the batteries and marinating a less that 5% voltage distortion, making this UPS configuration the right choice for many customers.

UPS ADJUSTABLE SPEED DRIVES

MOTORS CONTROLS INSTRUMENTATION PLC

 

 

 

Available Through:

INDUSTRIAL DIVISION

 

 

13131 West Little York Road, Houston, Texas 77041

 

Tel (713)466-0277

Fax (713)892-5212

 

*UPSISOREDUNDNT051209*

US (800)231-1412

Canada (800)872-2192

Mexico 01(800)527-1204

 

www.tic.toshiba.com

Copyright 12/2005

Page 2
Image 2
Toshiba Isolated-Redundant UPS System manual ISOLATED-REDUNDANT UPS Systems, Available Through

Isolated-Redundant UPS System specifications

Toshiba has long been a leader in providing innovative solutions for power management, and its Isolated-Redundant Uninterruptible Power Supply (UPS) system stands out as a testament to their commitment to quality and reliability. Designed to deliver exceptional performance and uptime, the Toshiba Isolated-Redundant UPS is ideal for mission-critical applications in data centers, hospitals, and industrial facilities.

One of the main features of this UPS system is its isolated design, which helps to protect sensitive equipment from electrical noise and disturbances. By incorporating isolation transformers, the system effectively decouples the load from the mains supply, resulting in clean and stable power. This feature is crucial for maintaining the integrity of operations in environments where power quality is paramount.

Another standout characteristic of the Toshiba Isolated-Redundant UPS is its redundancy capability. This system is designed to operate with multiple UPS units working in tandem, ensuring that if one unit fails, another can immediately take over without any interruption in power supply. This redundancy is essential for applications that cannot afford downtime, as it guarantees continuous operation and enhances overall system reliability.

The advanced technology utilized in this UPS system also includes a double-conversion online topology. This topology ensures that incoming AC power is converted to DC and then back to AC, providing an uninterruptible power flow to connected devices. This process effectively mitigates voltage fluctuations and allows the UPS to supply power during blackouts, line disturbances, or other unexpected power interruptions.

Efficiency is another critical aspect of the Toshiba Isolated-Redundant UPS. This system is designed to operate at high efficiency levels while minimizing heat generation. By adopting energy-saving technologies, Toshiba has created a UPS that not only offers reliable power but also contributes to lower operational costs over time.

Furthermore, the system boasts intelligent features such as remote monitoring and management capabilities. Users can easily access real-time data regarding the UPS status, performance metrics, and alert notifications, allowing for proactive maintenance and management of power resources.

In conclusion, the Toshiba Isolated-Redundant UPS system combines isolated design, redundancy, advanced technology, high efficiency, and intelligent monitoring to deliver unparalleled power protection for critical applications. With Toshiba’s reputation for excellence, organizations can trust this UPS to safeguard their operations around the clock.