Toshiba LF620F, LF654 specifications  About establishment environment,  Ordering Information

Models: LF620F LF654

1 14
Download 14 pages 14.66 Kb
Page 12
Image 12

TIC-LF654L

Table 3. Flow Rate and Flow velocity

(SI unit)

Unit: m3/h

Size

 

Flow rate

 

 

0.1 m/s

0.3 m/s

1.0 m/s

3.0

12

(mm)

m/s

m/s

 

 

 

15

0.06362

0.1908

0.6361

1.908

7.634

25

0.1767

0.5301

1.767

5.301

21.21

32

0.2895

0.8686

2.895

8.686

34.74

40

0.4523

1.357

4.523

13.57

54.29

50

0.7067

2.120

7.067

21.20

84.82

65

1.195

3.583

11.95

35.83

143.4

80

1.809

5.428

18.09

54.28

217.1

100

2.827

8.482

28.27

84.82

339.3

125

4.417

13.25

44.17

132.5

530.1

150

6.361

19.08

63.61

190.8

763.4

200

11.31

33.93

113.1

229.3

1,357

250

17.67

53.01

176.7

530.1

2,121

300

25.45

76.34

254.5

763.4

3,054

350

34.64

103.9

346.4

1,039

4,156

400

45.23

135.7

452.3

1,357

5,429

450

57.25

171.7

572.5

1,717

6,871

About establishment environment

Do not store or install the flowmeter:

Where there is direct sunlight.

Where excessive vibration or mechanical shock occurs.

Where high temperature or high humidity conditions exist.

Where corrosive atmospheres exist.

Places that can be submerged under water.

When placing the flowmeter temporarily on the floor, support it, i.e., with a block so that the

flowmeter does not topple over.

In areas like the following, there may be the case that infrared switches do not function correctly. (If these are unavoidable, use an appropriate cover.)

(1)Where unit (operation panel) is exposed to direct sunlight, reflection of light onto window pane and diffused light reflection.

(2)Where smoke and steam may occur.

(3)Where exposed to direct snow, ice or mud.

Ordering Information

1.When ordering the LF654 series flowmeters, refer to Tables 4 and 5 (Type Specification Codes). An entry must be made for each of the columns in each of these tables.

2.Fluid characteristics:

(1)Type of fluid to be measured and its characteristics

(2)Fluid temperature

(3)Fluid pressure

(4)Electrical conductivity of the fluid

3.Measuring range

4.I/O function setting

5.Ordering scope

Flow calibration data

6. Other items

Specifications other than standard items

Consult a Toshiba representative when choosing materials for lining, electrodes, and grounding rings.

Toshiba International Corp. (Houston) stocks

Hazardous location certification type flowmeters as standard inventory.

12

Page 12
Image 12
Toshiba LF620F, LF654 specifications  About establishment environment,  Ordering Information