Toshiba LF620F specifications  Model LF654 Detector

Models: LF620F LF654

1 14
Download 14 pages 14.66 Kb
Page 2
Image 2

TIC-LF654L

Fluid conductivity:

3µS/cm minimum

Fluid temperature:

-4 to 248 °F (-20 to +120 °C): PFA lined flowmeter

-4 to 140 °F (-20 to +60 °C): Polyurethane lined flowmeter

23 to 176 °F (- 5to +80 °C): Hard Rubber lined flowmeter

Ambient temperature:

-40 to 140 °F (-40 to +60 °C): PFA lined flowmeter

-4 to 140 °F (-20 to +60 °C):

PU lined and HR lined flowmeters

Structure:

Standard — IP 67 and NEMA 4X Watertight

Option — IP68 and NEMA 6P Submersible type allows for accidental submergence up to 15m for 48 hours. This option is only available when PU or HR liners are selected.

Power consumption:

Standard:10W(14VA)

at AC100V and Excitation current:0.2A MAX:15W (22VA)

MAX:17W(24VA) with PROFIBUS

Approved hazardous location certifications:

Model: LF654/LF620F and LF654/LF622F

cFMus Nonincendive for use in

hazardous (classified) locations:

Class I, II, III, Division 2, Groups A-G

Detector and converter combination:

LF650/LF620: Combined type for standard specification.

LF650/LF622: Separate type for standard specification.

LF654/LF620F: Combined type with Ex approval of Class I, II, III, Division 2 (cFMus).

LF654/LF622F: Separate type with Ex approval of Class I, II, III, Division 2 (cFMus).

Mount-Anywhere Technology:

With TOSHIBA’s unique magnetic field distribution technology the meter is highly immune to upstream flow disturbances.

A minimum of 1D (one diameter) length of upstream straight pipe from the flange is required to maintain the specification performance.

Note: The test results were obtained and demonstrated at TOSHIBA's flow calibration facility, Fuchu Japan.

Drinking water approvals:

PU and HR liner: NSF certified

Model LF654 Detector

Mounting style: Flange connection type

Fluid pressure:

-15 psi or -1.0 bar (-0.1 MPa) to the nominal pressure of the connection flange.

Note: Before shipping from the manufacturer, each detector unit is tested by the following test condition. Pressure… twice of the pressure index number

(ex. 300 psi in case of ASME B 16.5 class 150 flange) Time… 15 minutes

Connection flange standards:

ASME B16.5 class 150, ASME B16.5 class 300 EN1092-1 PN10, EN1092-1 PN16

JIS B 2220 10K, JIS B 2220 20K

Principal materials:

Case — carbon steel

Flange material — carbon steel

Linings

1/2” to 18” (15 to 450mm): PFA

1/2” to 18” (15 to 450mm): PU

4” to 18” (100 to 450mm): HR

Note: PFA liners are mechanically retained for full vacuum service (65 to 450 mm).

Electrodes

Type-Super smooth, polished with self cleaning finish, and non stick shape

316L stainless steel (std.) in case of PU and HR lining

Hastelloy C equivalent (std.) … in case of PFA lining

Note: Electrodes are mechanically buffed and electro-chemically polished.

Grounding rings — 316 stainless steel (std.)

Note: See Table 4 for optional materials and other related information.

Measuring tube material — 304 stainless steel Terminal box material — ADC12(Aluminum

alloy die casting)

Coating: Polyurethane resin coating (std.) gray colored

Dimensions and weights: See Figure 3, 4, 5 and 6.

Cable connection port: for separate type detectors. Cable gland

LF650: Provided as standard, G 1/2 male screws. LF654(with cFMus):Not provided, 3/4–14NPT

male screws are required.

Applicable diameter —

0.433 to 0.512 inch (11 to 13mm)

2

Page 2
Image 2
Toshiba LF620F specifications  Model LF654 Detector