Toshiba M300 manual Procedure 3 Connector and Cable Check

Models: M300

1 242
Download 242 pages 60.13 Kb
Page 80
Image 80

Troubleshooting Procedures

Procedure 3 Connector and Cable Check

LCD Module is connected to system board by an LCD/FL cable. FL inverter board is also connected to system board by an LCD/FL cable. And, fluorescent lamp is connected to FL inverter board by HV cable. Their cables may be disconnected from system board or FL inverter board. Disassemble the computer following the steps described in Chapter 4, Replacement Procedures.

If the connection is loose, reconnect firmly and restart the computer. If the problem still occurs, go to Procedure 4.

Satellite M300 and Satellite Pro M300 Maintenance Manual

36

Page 80
Image 80
Toshiba M300 manual Procedure 3 Connector and Cable Check