CARE AND MAINTENANCE

OWNER,S MANUAL - 23

CARE AND MAINTENANCE

POINTS TO NOTE

Operating Condition

• Temperature ranges suitable for unit operation are as follows.

MODE

INDOOR

OUTDOOR

COOL

21 ~ 32° c

21 ~ 43° c

HEAT

Below 27° c

Below 21° c

DRY

17 ~ 32° c

12 ~ 43° c

• When the unit operates above or below these conditions for a long time, system diagnostics may detect a malfunction and the unit will not operate properly.

• If the unit operates for a long time under abnormal situation of extremely high humidity, condensed water may drip from the unit.

Time Delay

There will be time delay between compressor turning off and turning on. (Cool and Dry mode : 3minutes,

Heat mode : 3minutes for RAS-18LKH-A/RAS-18LAH-A, 5minutes for RAS-22LKH-A/RAS-22LAH-A)

When heating operation starts, hot air delivery might be delayed due to a warm up period.

Minimum Operation Time

In normal operation, once the compressor turned on, there is a minimum operation time of 3 minutes regardless of ther mostat satisfaction.

Heating Features

When the unit starts in the heating mode, there will be a preheating period before the unit is ready to deliver warm air.

When the outdoor temperature is low, the heating capacity will be reduced. If the room air is not warm enough during severe winter conditions, use additional heating devices.

Defrost Operation

In the heating mode, when the outdoor coil is frosted, the indoor fan and outdoor fan will turn off while the compressor will turn on to remove the frost on the outdoor coil.

The defrost mode stops after 10 minutes or when the outdoor coil temperature is greater than 25° c.

When the power is off, the defrost operation is automatically conducted depending on frost accumulation on the outdoor coil.

Auto Recovery

When the electricity fails while the unit is operating, the unit memorizes the operating condition, and it will start operation automatically when the electricity is restored.