18
3-2. Outdoor Unit

RAV-SM562MUT-E / RAV-SP562AT-E

This compressor has 4-pole motor. The value when compressor frequency (Hz) is measured by a clamp
meter becomes 2 times of No. of compressor revolutions (rps).
Outdoor unit
Strainer
Strainer
Packed valve
Outer dia. Ø12.7
Packed valve
Outer dia. Ø6.4
TS sensor
Accumulator
(1500cc)
TD sensor
TO sensor
TE
sensor
4-way valve
(STF-0213Z)
Ø25 × L160
Rotary compressor
(DA220A2F-20L)
Heat exchangerØ8
1 row 30 stages
FP1.3 flat fin
Capillary
Ø3×Ø2×
L530
Ø25 × L210
Muffler
R410A 1.5 kg
Cooling
Heating
PsPd
Modulating
(PMV)
(SKV-18D26)
Standard
Cooling Overload
Low load
Standard
Heating Overload
Low load
Pressure
(MPa)
Pd Ps
2.71 1.03
3.48 1.16
1.92 0.74
2.22 0.72
3.47 1.16
1.79 0.25
Pipe surface temperature (°C)
Discharge Suction Indoor heat Outdoor heat
exchanger exchanger
(TD) (TS) (TC) (TE)
75 15 10 38
81 20 16 51
34 5 2 11
62 6 38 2
81 20 55 15
71 16 30 –18
Compressor
revolutions per
second (rps)
43
44
24
41
41
70
Indoor
fan
HIGH
HIGH
LOW
HIGH
LOW
HIGH
Indoor/Outdoor
temp. conditions
(DB/WB) (°C)
Indoor Outdoor
27/19 35/
32/24 43/
18/15.5 5/
20/7/6
30/24/18
15/
20/(70%)