67
Refer to Characteristics-3 and 4.
For RAV-SM562AT-E, RAV-SM563AT-E,
RAV-SP404AT-E, RAV-SP454AT-E,
replace control P.C. board.
Check TE sensor.
Defect Replace
Correct connection
of connector.
Replace TD, TO,
and TC sensors.
Check CDB.
Defect Replace
Check TE, TC, TS sensors.
Replace electron expansion valve.
Replace fan motor.
Correct coming-off.
Check charged refrigerant amount.
Check liquid/gas valves.
Check abnormal overload.
Does PMV normally operate?
Are characteristics of
TD, TO, TC sensor resistance
values normal?
Is fan motor normal?
Does cooling outdoor fan
normally operate?
Is connection of
cabling connector normal?
Is connection of
connector normal?
Do not TD and TO sensors
come off the detection part?
Is high-voltage
protective operation by
TE sensor normal?
Correct connection
of cabling connector.
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES
[P04 error]