Outdoor Unit

Installation Manual

4 PRECAUTIONS FOR SAFETY

Installing, starting up, and servicing air--conditioning equipment can be hazardous due to system pressures, electrical components, and equipment location (roofs, elevated structures, etc.).

Only trained, qualified installers and service mechanics should install, start--up, and service this equipment. Untrained personnel can perform basic maintenance functions such as cleaning coils. All other operations should be performed by trained service personnel.

When working on the equipment, observe precautions in the literature and on tags, stickers, and labels attached to the equipment.

Follow all safety codes. Wear safety glasses and work gloves. Keep quenching cloth and fire extinguisher nearby when brazing. Use care in handling, rigging, and setting bulky equipment.

Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit. Consult local building codes and National Electrical Code (NEC) for special requirements. Recognize safety information. This is the safety--alert symbol . When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury.Understand these signal words: DANGER, WARNING, and CAUTION. These words are used with the safety--alert symbol.

DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

WARNING

Ask an authorized dealer or qualified installation professional to install/maintain the air conditioner. Perform installation work properly according to the Installation Manual.

Inappropriate installation may result in water leakage, electric shock or fire.

Be sure to ground the equipment

Improper grounding may cause an electric shock.

Do not connect ground wires to gas pipes, water pipes, lightning rods or ground wires for telephone wires.

Turn off the circuit breaker before attempting any electrical work and maintenance. Make sure the circuit breaker is off. Failure to do so may cause electric shock.

Use an exclusive power circuit for the air conditioner. Use the rated voltage.

When moving the air conditioner for installation to another place, be very careful not to allow the specified refrigerant (R410A) to become mixed with any other gaseous body into the refrigeration cycle.

If air or any other gas mixes with the refrigerant, the gas pressure in the refrigeration cycle will become abnormally high and it may result in the pipe bursting or personal injuries.

Do not modify this unit by removing any of the safety guards or by by-passing any of the safety interlock switches.

Do not touch the intake or aluminium fins of the outdoor unit. Doing so may result in injury.

Tighten the flare nut with a torque wrench in the specified manner.

Excessive tightening of the flare nut may cause a crack in the flare nut after a long period, which may result in refrigerant leakage.

Install the air conditioner securely in a location where the base can sustain the weight of the unit adequately.

If refrigerant gas has leaked during the installation work, ventilate the room immediately. If the leaked refrigerant gas comes in contact with fire, noxious gas may be generated.

After the installation work, confirm that refrigerant gas does not leak.

If refrigerant gas leaks into the room and flows near a fire source, such as a cooking range, noxious gas may be generated.

Electrical work must be performed by a qualified electrician in accordance with the NEC or local code. Make sure the air conditioner uses an exclusive power supply.

An insufficient power supply capacity or inappropriate installation may cause fire.

Use only the specified wiring during the unit installation. Ensure that all terminals are securely fixed, so preventing any external forces having a negative effect on the terminals.

5-EN

– 5 –

Page 6
Image 6
Toshiba RAV-SP360AT2-UL, RAV-SP300AT2-UL, RAV-SP420AT2-UL Precautions for Safety, Be sure to ground the equipment

RAV-SP420AT2-UL, RAV-SP300AT2-UL, RAV-SP360AT2-UL specifications

Toshiba has established itself as a leader in HVAC technology, providing solutions that cater to diverse climate control needs. Among its notable models are the Toshiba RAV-SP300AT2-UL, RAV-SP420AT2-UL, and RAV-SP360AT2-UL. Each of these units is designed to deliver efficient cooling and heating, suitable for both residential and commercial applications.

The RAV-SP300AT2-UL is a compact air conditioning unit that emphasizes energy efficiency. With a cooling capacity of 30,000 Btu/h and a heating capacity that mirrors this output, the unit is an ideal choice for moderate-sized spaces. One of its key features is the use of inverter technology, which allows the compressor to adjust its speed according to the cooling demand. This not only reduces energy consumption but also ensures a consistent indoor climate.

Moving to the RAV-SP420AT2-UL, this model offers higher performance with a cooling capacity of 42,000 Btu/h. It maintains energy efficiency while providing robust climate control capabilities. The RAV-SP420AT2-UL is equipped with advanced filtration systems that enhance indoor air quality by removing dust, allergens, and other pollutants. Additionally, the unit features a quiet operation mode that minimizes noise, making it suitable for environments where comfort and tranquility are paramount.

The RAV-SP360AT2-UL occupies a middle ground with a cooling capacity of 36,000 Btu/h. Like its counterparts, it harnesses inverter technology for optimum efficiency. This model is particularly noted for its versatility, as it can effectively serve a wide range of commercial applications. It also boasts smart technology integration, allowing users to control their HVAC systems remotely via smartphones or smart home systems.

All three models are constructed with durable materials designed to withstand varying weather conditions. They also feature a self-diagnostic system that assists technicians in identifying issues quickly, thereby minimizing downtime. Furthermore, Toshiba's commitment to sustainability is evident in these units, as they are designed with eco-friendly refrigerants that comply with global environmental standards.

In conclusion, Toshiba's RAV-SP300AT2-UL, RAV-SP420AT2-UL, and RAV-SP360AT2-UL represent the forefront of HVAC innovation. With their unique features, energy efficiency, and advanced technologies, these air conditioning systems provide reliable performance tailored to the needs of users, ensuring comfort and satisfaction in any environment.