Data Error Rate
Max | ||
Max (Mode 1) | ||
Max (Mode 2) | ||
| 10 | |
Data Buffer | 2MB | |
Reliability |
|
|
MTBF | 100,000 hours | |
Power ON Hours | 5,436 hours/year | |
ON/OFF Cycles | 313 cycles/year | |
Number of Access | 600,000 accesses/year | |
Operating Duty Cycle | 20% of Power ON time (Reading/Seeking) | |
2% of Power ON time (Writing/Seeking) |
|
|
MTTR | 0.5 hours |
Environmental
Ambient Temperature
Operating
Storage
Shipping
Temperature Gradient
Operating
Storage/Shipping
Relative Humidity
Operating
Storage/Shipping
Vibration
Operating (5 to 500 Hz) (read) Operating (5 to 500Hz) (write)
Transporting (with packing) (10 to 25 Hz)
Shock
Acoustical Noise
14
5º to 50º C (41º to 122º F)
11º C /hour (max)
20º C /hour (max)
8% to 80%
5% to 95% (wet bulb 40 C max)
2.45m/s2 (0.25G)
2.45m/s2 (0.25G)
9.8m/s2 (1.0G)
9.8m/s2 (1.0G)
490 m/s2 [50G]
40dB