Figure 3-3 Equipotential Bonding

Gigabit Uplink Unmanaged Switch

Grounding Terminal

Equipotential Bonding Cable

Ground Cable

Grounding Bar

Figure 3-3 Equipotential Bonding

When equipotential bonding, please note that the cable should be copper wrapped Kelly with its area being 6mm2 at least. The shorter cable the better, and use a grounding bar to establish an equipotential bonding point.

Note: The equipotential bonding cable is not provided with our product. If needed, please self purchase it.

3.4 Use Lightning Arrester

Power lightning arrester and signal lightning arrester are used for lighting protection.

Power lightning arrester is used for limiting the voltage surge due to a lightning. If an outdoor AC power cord should be directly connected to the device, please use a power lightning arrester.

Note: Power lightning arrester is not provided with our product. If needed, please self purchase it.

Lightning Protection 3.4 Use Lightning Arrester 13