Trane 4YCY4060A, 4YCY4024A manual Performance Data Cooling, Total

Models: 4YCY4024A 4YCY4060A

1 29
Download 29 pages 59.65 Kb
Page 10
Image 10
Manual background

Performance Data Cooling

4YCY4042A1 AT 1400 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)

OD

ID

TOT

SENS CAP AT ENTERING DB TEMP

TOTAL

AMB

WB

CAP

72

75

78

80

KW

 

59

40.3

34.1

38.4

40.3

40.3

3.1

85

63

42.0

27.7

31.9

36.2

39.0

3.1

67

45.3

21.8

26.1

30.3

33.2

3.2

 

 

71

48.9

15.9

20.2

24.4

27.3

3.2

 

 

 

 

 

 

 

 

 

59

37.6

32.9

37.2

37.6

37.6

3.4

95

63

39.2

26.6

30.8

35.1

37.9

3.5

67

42.2

20.7

24.9

29.2

32.0

3.5

 

 

71

45.6

14.8

19.1

23.3

26.2

3.5

 

 

 

 

 

 

 

 

 

59

34.9

31.7

34.9

34.9

34.9

3.8

105

63

36.4

25.4

29.7

33.9

36.4

3.8

67

39.2

19.6

23.8

28.1

30.9

3.8

 

 

71

42.3

13.7

18.0

22.2

25.1

3.8

 

 

 

 

 

 

 

 

 

59

32.2

30.5

32.2

32.2

32.2

4.1

115

63

33.6

24.3

28.6

32.8

33.6

4.1

67

36.2

18.5

22.7

26.9

29.8

4.2

 

 

71

39.0

12.6

16.8

21.1

23.9

4.2

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

 

AIR FLOW

CAPACITY

 

TOTAL POWER

 

RATE, CFM

MULTIPLIER

 

MULTIPLIER

LOW

1225

0.97

 

0.98

HIGH

1575

1.03

 

1.02

 

 

 

 

ARI RATING FOR COOLING

 

CFM

CAPACITY (A) TEST

SEER

EER

1360

42000

 

14.25

12.00

 

 

 

 

 

ARI Standard Capacity Rating Conditions

ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

4YCY4048A1/3 AT 1600 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)

OD

ID

TOT

SENS CAP AT ENTERING DB TEMP

TOTAL

AMB

WB

CAP

72

75

78

80

KW

 

59

45.3

38.2

42.9

45.3

45.3

3.6

85

63

47.2

31.0

35.7

40.5

43.7

3.6

67

50.9

24.4

29.1

33.9

37.1

3.7

 

 

71

55.0

17.7

22.5

27.3

30.4

3.7

 

59

42.7

37.0

41.7

42.7

42.7

3.9

95

63

44.5

29.8

34.6

39.3

42.6

4.0

67

48.0

23.2

28.0

32.8

36.0

4.0

 

 

71

51.8

16.7

21.4

26.2

29.4

4.0

 

59

40.1

35.8

40.1

40.1

40.1

4.3

105

63

41.8

28.7

33.5

38.3

41.4

4.4

67

45.0

22.2

27.0

31.7

34.9

4.4

 

 

71

48.6

15.6

20.4

25.1

28.3

4.4

 

59

37.5

34.7

37.5

37.5

37.5

4.7

115

63

39.1

27.7

32.4

37.2

39.1

4.7

67

42.1

21.1

25.8

30.6

33.8

4.8

 

 

71

45.5

14.5

19.3

24.0

27.2

4.8

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

 

AIR FLOW

CAPACITY

 

TOTAL POWER

 

RATE, CFM

MULTIPLIER

 

MULTIPLIER

LOW

1400

0.97

 

0.98

HIGH

1800

1.03

 

1.02

 

 

 

 

ARI RATING FOR COOLING

 

CFM

CAPACITY (A) TEST

SEER

EER

1605

48000

 

14.20

11.90

 

 

 

 

 

ARI Standard Capacity Rating Conditions

ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

4YCY4060A1/3 AT 2000 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)

OD

ID

TOT

SENS CAP AT ENTERING DB TEMP

TOTAL

AMB

WB

CAP

72

75

78

80

KW

 

59

56.5

47.6

53.5

56.5

56.5

4.4

85

63

58.9

38.5

44.5

50.5

54.4

4.4

67

63.5

30.2

36.2

42.2

46.2

4.5

 

 

71

68.5

21.9

27.8

33.8

37.8

4.5

 

59

53.1

46.0

52.0

53.1

53.1

4.8

95

63

55.4

37.0

43.1

49.0

53.0

4.9

67

59.7

28.8

34.8

40.7

44.8

5.0

 

 

71

64.4

20.5

26.4

32.4

36.4

5.0

 

59

49.7

44.5

49.7

49.7

49.7

5.3

105

63

51.9

35.7

41.6

47.6

51.6

5.3

67

55.9

27.4

33.3

39.3

43.3

5.4

 

 

71

60.3

19.1

25.0

31.0

35.0

5.4

 

59

46.4

43.0

46.4

46.4

46.4

5.8

115

63

48.3

34.2

40.2

46.2

48.3

5.8

67

52.1

26.0

32.0

37.9

41.9

5.9

 

 

71

56.2

17.7

23.7

29.6

33.7

5.9

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

 

AIR FLOW

CAPACITY

 

TOTAL POWER

 

RATE, CFM

MULTIPLIER

 

MULTIPLIER

LOW

1750

0.97

 

0.98

HIGH

2250

1.03

 

1.02

 

ARI RATING FOR COOLING

 

CFM

CAPACITY (A) TEST

SEER

EER

1799

58500

 

14.00

11.90

ARI Standard Capacity Rating Conditions

ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

10

Page 10
Image 10
Trane 4YCY4060A, 4YCY4024A manual Performance Data Cooling, Total