Trane 4YCY4060A manual Indoor Blower Performance, 4YCY4024A1064

Models: 4YCY4024A 4YCY4060A

1 29
Download 29 pages 59.65 Kb
Page 14
Image 14
4YCY4024A1064

Indoor Blower Performance

Heating Airflow, horizontal or downflow from .2 to .6” wg.

4YCY4024A1064

Switch Settings

Selection

Nominal Airflow

 

 

 

Low Stage

High Stage

7-OFF

8-OFF

A

600

850

7-ON

8-OFF

B

625

900

7-OFF

8-ON

C

650

925

7-ON

8-ON

D

700

975

4YCY4030A

Switch Settings

 

Selection

Nominal Airflow

 

 

 

 

Low Stage

High Stage

7-OFF

8-OFF

 

A

725

1000

7-ON

8-OFF

 

B

775

1075

7-OFF

8-ON

 

C

850

1150

7-ON

8-ON

 

D

925

1250

 

 

 

 

 

 

 

 

4YCY4036A*075

 

Switch Settings

 

Selection

Nominal Airflow

 

 

 

 

Low Stage

High Stage

7-OFF

8-OFF

 

A

725

1000

7-ON

8-OFF

 

B

775

1075

7-OFF

8-ON

 

C

850

1150

7-ON

8-ON

 

D

925

1250

 

 

*

can be 1 or

3

 

 

 

 

 

 

 

4YCY4036A*096

 

Switch Settings

 

Selection

Nominal Airflow

 

 

 

 

Low Stage

High Stage

7-OFF

8-OFF

 

A

825

1100

7-ON

8-OFF

 

B

875

1175

7-OFF

8-ON

 

C

950

1275

7-ON

8-ON

 

D

1025

1375

* can be 1 or 3

4YCY4042A

Switch Settings

 

 

Selection

 

Nominal Airflow

 

 

 

 

 

 

Low Stage

High Stage

7-OFF

8-OFF

 

 

A

 

1075

 

1375

 

7-ON

8-OFF

 

 

B

 

1100

 

1450

 

7-OFF

8-ON

 

 

C

 

1150

 

1500

 

7-ON

8-ON

 

 

D

 

1200

 

1575

 

 

 

 

 

 

 

 

 

4YCY4048A*096

 

 

Switch Settings

 

 

Selection

 

Nominal Airflow

 

 

 

 

 

 

Low Stage

High Stage

 

7-OFF

8-OFF

 

 

A

1075

 

1375

 

7-ON

8-OFF

 

 

B

1100

 

1450

 

7-OFF

8-ON

 

 

C

1150

 

1500

 

7-ON

8-ON

 

 

D

1200

 

1575

 

 

 

*

can be 1 or

3

 

 

 

 

 

 

 

 

 

 

 

4YCY4048A*120

 

 

Switch Settings

 

 

Selection

 

Nominal Airflow

 

 

 

 

 

 

Low Stage

High Stage

 

7-OFF

8-OFF

 

 

A

1050

 

1500

 

7-ON

8-OFF

 

 

B

1100

 

1575

 

7-OFF

8-ON

 

 

C

1150

 

1625

 

7-ON

8-ON

 

 

D

1200

 

1700

 

 

 

*

can be 1 or

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4YCY4060A

 

 

Switch Settings

 

 

Selection

 

Nominal Airflow

 

 

 

Low Stage

High Stage

 

7-OFF

8-OFF

 

 

A

1375

 

1800

 

7-ON

8-OFF

 

 

B

1450

 

1900

 

7-OFF

8-ON

 

 

C

1525

 

1975

 

7-ON

8-ON

 

 

D

1575

 

2075

 

14

Page 14
Image 14